首页> 美国卫生研究院文献>American Journal of Physiology - Heart and Circulatory Physiology >The role of dye affinity in optical measurements of Cai2+ transients in cardiac muscle
【2h】

The role of dye affinity in optical measurements of Cai2+ transients in cardiac muscle

机译:染料亲和力在光学测量心肌中Cai2 +瞬变中的作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Previous experiments in cultures of neonatal rat myocytes demonstrated that the shape of Cai2+ transients measured using high-affinity Ca2+-sensitive dyes may be misrepresented. The purpose of this study was to examine the role of dye affinity in Cai2+ measurements in intact adult cardiac tissue by comparing optical recordings obtained with high- and low-affinity dyes. Experiments were carried out in porcine left ventricular (LV) wedge preparations stained locally by intramural injection via microcapillaries (diameter = 150 μm) with a low-affinity Ca2+-sensitive dye Fluo-4FF or Fluo-2LA (nominal Kd, ∼7–10 μmol/l), high-affinity dye Rhod-2 (Kd = 0.57 μmol/l), and Fluo-4 or Fluo-2MA (Kd, ∼0.4 μmol/l); in addition, tissue was stained with transmembrane potential (Vm)-sensitive dye RH-237. Optical recordings of Vm and Cai2+ were made using optical fibers (diameter = 325 μm) glued with the microcapillaries. The durations of Cai2+ transients measured at 50% level of recovery (CaD50) using high-affinity Fluo-4/Fluo-2MA dyes were up to ∼81% longer than those measured with low-affinity Fluo-4FF/Fluo-2LA at long pacing cycle lengths (CL). In Fluo-4/Fluo-2MA measurements at long CLs, Cai2+ transients often (∼50% of cases) exhibited slow upstroke rise and extended plateau. In Rhod-2 measurements, CaD50 was moderately longer (up to ∼35%) than in Fluo-4FF recordings, but Cai2+ transient shapes were similar. In all series of measurements, mean action potential duration values were not significantly different (P > 0.05). The delays between Vm and Cai2+ upstrokes were comparable for low- and high-affinity dyes (P > 0.05). In conclusion, measurements of Cai2+ transient in ventricular myocardium are strongly affected by the affinity of Ca2+ dyes. The high-affinity dyes may overestimate the duration and alter the shape of Cai2+ transients.
机译:先前在新生大鼠心肌细胞培养物中进行的实验表明,使用高亲和力的Ca 2 + 敏感染料测量的Cai 2 + 瞬态的形状可能会被错误表示。这项研究的目的是通过比较用高亲和力和低亲和力染料获得的光学记录来检查染料亲和力在完整成人心脏组织的Cai 2 + 测量中的作用。在猪左心室(LV)楔形制剂中进行实验,该制剂通过壁内注射通过微毛细管(直径= 150μm)与低亲和力的Ca 2 + 敏感染料Fluo-4FF或Fluo- 2LA(标称Kd,约7-10μmol/ l),高亲和力染料Rhod-2(Kd = 0.57μmol/ l)和Fluo-4或Fluo-2MA(Kd,约0.4μmol/ l);另外,组织用跨膜电位(Vm)敏感染料RH-237染色。 Vm和Cai 2 + 的光学记录是通过用微毛细管粘合的光纤(直径= 325μm)进行的。使用高亲和力Fluo-4 / Fluo-2MA染料在50%恢复水平(CaD50)下测得的Cai 2 + 瞬变的持续时间比使用低亲和力的Fluo-4 / Fluo-2MA染料长约81% Fluo-4FF / Fluo-2LA的起搏周期长(CL)长。在长CL处的Fluo-4 / Fluo-2MA测量中,Cai 2 + 瞬态经常(约占50%)表现出较慢的上冲上升和平稳期。在Rhod-2测量中,CaD50比Fluo-4FF记录适度更长(约35%),但Cai 2 + 瞬态形状相似。在所有系列的测量中,平均动作电位持续时间值无显着差异(P> 0.05)。对于低亲和力和高亲和力染料,Vm和Cai 2 + 上冲程之间的延迟是可比的(P> 0.05)。总之,Ca 2 + 染料的亲和力强烈影响心室心肌中Cai 2 + 瞬变的测量。高亲和力染料可能会高估持续时间并改变Ca i 2 + 瞬态的形状。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号