Accuracy of Subcutaneous Continuous Glucose Monitoring in Critically Ill Adults: Improved Sensor Performance with Enhanced Calibrations

机译:危重成年人皮下连续血糖监测的准确性:通过增强的校准提高传感器性能

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Objective: Accurate real-time continuous glucose measurements may improve glucose control in the critical care unit. We evaluated the accuracy of the FreeStyle® Navigator® (Abbott Diabetes Care, Alameda, CA) subcutaneous continuous glucose monitoring (CGM) device in critically ill adults using two methods of calibration.>Subjects and Methods: In a randomized trial, paired CGM and reference glucose (hourly arterial blood glucose [ABG]) were collected over a 48-h period from 24 adults with critical illness (mean±SD age, 60±14 years; mean±SD body mass index, 29.6±9.3 kg/m2; mean±SD Acute Physiology and Chronic Health Evaluation score, 12±4 [range, 6–19]) and hyperglycemia. In 12 subjects, the CGM device was calibrated at variable intervals of 1–6 h using ABG. In the other 12 subjects, the sensor was calibrated according to the manufacturer's instructions (1, 2, 10, and 24 h) using arterial blood and the built-in point-of-care glucometer.>Results: In total, 1,060 CGM–ABG pairs were analyzed over the glucose range from 4.3 to 18.8 mmol/L. Using enhanced calibration median (interquartile range) every 169 (122–213) min, the absolute relative deviation was lower (7.0% [3.5, 13.0] vs. 12.8% [6.3, 21.8], P<0.001), and the percentage of points in the Clarke error grid Zone A was higher (87.8% vs. 70.2%).>Conclusions: Accuracy of the Navigator CGM device during critical illness was comparable to that observed in non–critical care settings. Further significant improvements in accuracy may be obtained by frequent calibrations with ABG measurements.
机译:>目的:准确,实时的连续葡萄糖测量可以改善重症监护病房的血糖控制。我们使用两种校准方法评估了危重成年人中FreeStyle ® Navigator ®(Abbott Diabetes Care,阿拉米达,加利福尼亚)皮下连续血糖监测(CGM)设备的准确性。 。>受试者和方法:在一项随机试验中,在48小时内从24名危重疾病(平均年龄±SD岁)的成年人中收集了配对的CGM和参考葡萄糖(小时动脉血葡萄糖[ABG])。 ,60±14岁;平均±SD体重指数,29.6±9.3 kg / m 2 ;平均±SD急性生理学和慢性健康评估得分,12±4 [范围,6-19])和高血糖症。在12名受试者中,使用ABG以1–6µh的可变间隔校准了CGM设备。在其他12名受试者中,使用动脉血和内置即时血糖仪根据制造商的说明(1、2、10和24小时)对传感器进行了校准。>结果:在葡萄糖范围为4.3至18.8GMmmol / L的范围内,共分析了1,060对CGM-ABG。每169(122-213)分钟使用增强的校准中位数(四分位间距),则绝对相对偏差较低(7.0%[3.5,13.0]对12.8%[6.3,21.8],P <0.001),并且百分比Clarke错误网格A区中的点更高(87.8%比70.2%)。>结论:危重病患者期间Navigator CGM设备的准确性与非危重病患者的观察结果相当。通过使用ABG测量进行频繁的校准,可以进一步提高准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号