首页> 美国卫生研究院文献>International Journal of Molecular Sciences >An Investigation on the Application of Pulsed Electrodialysis Reversal in Whey Desalination
【2h】

An Investigation on the Application of Pulsed Electrodialysis Reversal in Whey Desalination

机译:脉冲电渗析逆转在乳清淡化中的应用研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Electrodialysis (ED) is frequently used in the desalination of whey. However, the fouling onto the membrane surface decreases the electrodialysis efficiency. Pulsed Electrodialysis Reversal (PER), in which short pulses of reverse polarity are applied, is expected to decrease the fouling onto membrane surface during ED. Three (PER) regimes were applied in the desalination of acid whey (pH ≤ 5) to study their effects on the membrane fouling and the ED efficiency. The PER regimes were compared to the conventional ED as the control. For each regime, two consecutive runs were performed without any cleaning step in-between to intensify the fouling. After the second run, the membranes were subjected to the Scanning electron microscope (SEM) imaging and contact angle measurement to investigate the fouling on the membrane surface in different regimes. The ED parameters in the case of conventional ED were almost the same in the first and the second runs. However, the parameters related to the ED efficiency including ED capacity, ash transfer, and ED time, were deteriorated when the PER regimes were applied. The contact angle values indicated that the fouling on the diluate side of anion exchange membranes was more intensified in conventional ED compared to the PER regimes. The SEM images also showed that the fouling on the diluate side of both cation and anion exchange membranes under PER regimes was reduced in respect to the conventional ED. However, the back transfer to the diluate compartment when the reverse pulse was applied is dominant and lowers the ED efficiency slightly when the PER is applied.
机译:电渗析(ED)通常用于乳清的脱盐。然而,在膜表面上的结垢降低了电渗析效率。脉冲电渗析逆转(PER)(其中施加了反极性的短脉冲)有望减少ED期间膜表面的结垢。三种(PER)方案用于酸乳清(pH≤5)的脱盐,以研究它们对膜结垢和ED效率的影响。将PER方案与常规ED进行比较。对于每种方案,在不进行任何清洁步骤的情况下进行了两次连续运行以增强结垢。第二次运行后,对膜进行扫描电子显微镜(SEM)成像和接触角测量,以研究在不同情况下膜表面的结垢情况。在常规ED的情况下,ED参数在第一轮和第二轮中几乎相同。但是,当采用PER方案时,与ED效率相关的参数(包括ED容量,灰分转移和ED时间)会变差。接触角值表明,与PER方案相比,常规ED中阴离子交换膜稀释液一侧的结垢更加严重。 SEM图像还显示,相对于传统的ED,在PER方案下阳离子和阴离子交换膜的稀释液侧的结垢都减少了。但是,当施加反向脉冲时,向稀释液隔室的反向转移占主导,当施加PER时,ED效率会稍微降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号