首页> 美国卫生研究院文献>Acta Orthopaedica >Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis
【2h】

Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis

机译:植入金属对金属髋关节假体后长达11年的结果和血清离子测定

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Background and purpose Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age.>Methods 109 patients (134 joint replacements) were followed prospectively for mean 9 (7–11) years. The evaluation included clinical score, radiographic assessment, and blood sampling for ion level determination.>Results At the final review, 12 hips had been revised, mainly because of aseptic loosening of the socket. Using revision for aseptic loosening as the endpoint, the survival rate at 9 years was 91% for the cup and 99% for the stem. In addition, 35 hips showed radiolucent lines at the bone-cement interface of the acetabulum and some were associated with osteolysis. The median serum cobalt and chromium levels were relatively constant over time, and were much higher than the detection level throughout the study period. The cobalt level was 1.5 μg/L 1 year after implantation, and 1.44 μg/L 9 years after implantation.>Interpretation Revisions for aseptic loosening and radiographic findings in the sockets led us to halt metal-on-metal-backed polyethylene cemented hip arthroplasty procedures. If the rigidity of the cemented socket is a reason for loosening, excessive release of metal ions and particles may be involved. Further investigations are required to confirm this hypothesis and to determine whether subluxation, microseparation, and hypersensitivity also play a role.
机译:>背景和目的对于金属对金属髋关节置换术的长期效果知之甚少。我们对60岁以下的患者进行了一系列的金属对金属聚乙烯支持的骨水泥髋关节置换术的评估。>方法前瞻性随访了109例患者(134个关节置换),平均9例(7– 11)年。评估包括临床评分,影像学评估和血液采样以测定离子水平。>结果在最后的评估中,已对12髋进行了修订,这主要是因为无菌松脱了承窝。以无菌性松动翻修术为终点,杯的9年生存率为91%,杆的为9%。此外,有35个髋关节在髋臼的骨水泥界面处显示了射线可透线,其中一些与溶骨有关。血清钴和铬的中位数水平随时间变化相对恒定,并且在整个研究期间均远高于检测水平。植入后1年的钴水平为1.5μg/ L,植入后9年的钴水平为1.44μg/ L。>解释修订后的窝窝无菌性松动和影像学检查导致我们停止了金属对金属支持聚乙烯的髋关节置换术。如果胶合插座的刚度是造成松动的原因,则可能涉及金属离子和颗粒的过度释放。需要进一步的研究来证实这一假说,并确定半脱位,微分离和超敏反应是否也起作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号