There has been growing concern regarding the systemic and local effects of metal ions released from metal-on-metal (MOM) total hip replacements. There is limited data comparing the serum levels of metal ions after converting MOM to metal-on-polyethylene (MOP) bearings during revision total hip arthroplasty (THA). The purpose of this study was to report observed changes in the serum metal ion concentration following the revision of MOM bearings in THA. From Sept. 2010 to Nov. 2011, 23 patients with symptomatic MOM THA were revised to a MOP bearing. 10 patients had bilateral MOM THAs and underwent revision of the more symptomatic side only. All patients had normal renal function based on preoperative lab values. Serum levels of cobalt and chromium were tested prior to the revision, and were repeated between 6 weeks and 7 months postoperatively. Changes in levels of cobalt and chromium were analyzed with the Wilcoxon signed-rank test. Average cobalt serum levels were 30.6 μg/L preoperatively and 6.8 μg/L postoperatively. Average serum chromium levels were 19.7 μg/L preoperatively and 9.0 μg/L postoperatively. Both decreases were statistically significant (p < 0.0001). No patient had an increase in serum levels following the revision surgery. Both before and after the revision, patients with bilateral MOM THA exhibited higher blood levels of cobalt and chromium compared to patients with a unilateral MOM THA. Of those with unilateral MOM THAs, six patients (46%) had cobalt levels < 1.0 μg/L and four patients (31%) had chromium levels < 1.0 μg/L following revision. Serum levels of cobalt and chromium decrease following the conversion of a MOM to a MOP bearing surface. Cobalt levels appeared to decrease more rapidly than chromium levels at short term follow-up, the significance of which remains to be determined. Few patients had normal serum levels at early follow-up after revision.
机译:关于金属离子(MOM)总髋关节置换释放的金属离子的全身和局部效果越来越受到担忧。在修订过程中,在转化MOM到金属乙烯(MOP)轴承后,数据比较了金属离子的血清水平有限。本研究的目的是报告在修改母亲在THA的修订后观察到的血清金属离子浓度的变化。从2010年9月到2011年11月,23例患有症状妈妈患者被修改为拖把轴承。 10名患者患有双侧妈妈,并且仅接受了更具症状的侧面。所有患者都具有基于术前实验室值的正常肾功能。在修改之前测试血清钴和铬水平,并在术后6周和7个月之间重复。用氟胞氧辛符号测量试验分析钴和铬水平的变化。术后平均钴血清水平为30.6μg/ L和术后6.8μg/ L.术后平均血清铬水平为19.7μg/ L和术后9.0μg/ L.两者降低均有统计学意义(P <0.0001)。修订手术后没有患者在血清水平增加。在修改之前和之后,与单侧妈妈Tha的患者相比,双侧妈妈妈妈患者表现出更高的血液水平和铬。在单侧妈妈THA的那些中,六名患者(46%)的钴水平<1.0μg/ L和4名患者(31%)进行铬水平<1.0μg/ L后修订。在将MOM转化为拖把轴承表面之后,血清钴和铬的血清水平降低。在短期随访中,钴水平似乎比铬水平更快地减少,其意义仍有待确定。在修改后,很少有患者在早期后续进行正常的血清水平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号