Evaluations of several commercial presence-absence (P-A) test kits were performed over a 6-month period in 1990 by using the Ontario Ministry of the Environment (MOE) P-A test for comparison. The general principles of the multiple-tube fermentation technique formed the basis for conducting the product evaluations. Each week, a surface water sample was diluted and inoculated into 25 99-ml dilution blanks for each of three dilutions. The inoculated dilution blanks from each dilution series were randomly sorted into sets of five. Three of these sets were inoculated into the P-A test kits or vice versa, as required. The other two sets were passed through membrane filters, and one set of five membrane filters was placed onto m-Endo agar LES to give replicate total coliform counts and the other set was placed onto m-TEC agar to give replicate fecal coliform results. A statistical analysis of the results was performed by a modified logistic transform method, which provided an improved way to compare binary data obtained from the different test kits. The comparative test results showed that three of the four commercial products tested gave very good levels of recovery and that the fourth commercial product gave only fair levels of recovery when the data were compared with the data from MOE P-A tests and membrane filter tests. P-A bottles showing positive results after 18 h of incubation that were subcultured immediately in ECMUG tubes frequently could be confirmed as containing total coliforms, fecal coliforms, or Escherichia coli after 6 h of incubation; thus, the total incubation time was only 24 h.(ABSTRACT TRUNCATED AT 250 WORDS)
机译:1990年,通过使用安大略省环境部(MOE)的P-A测试进行比较,对几种商业存在(P-A)测试套件进行了评估。多管发酵技术的一般原理构成了进行产品评估的基础。每周,将地表水样品稀释并接种到25种99-ml稀释空白液中,分别用于三种稀释液。将来自每个稀释系列的接种的稀释空白样品随机分为五组。根据需要将其中三套接种到P-A测试套件中,反之亦然。将另两组通过膜滤器,并将一组五个膜滤器置于m-Endo琼脂LES上,以复制大肠菌总数,另一组置于m-TEC琼脂上,以得到粪便大肠菌的重复结果。通过改进的逻辑变换方法对结果进行统计分析,该方法提供了一种改进的方法来比较从不同测试套件获得的二进制数据。对比测试结果显示,当将数据与MOE P-A测试和膜过滤器测试的数据进行比较时,所测试的四种商用产品中的三种具有非常好的回收率,而第四种商用产品仅具有相当的回收率。孵育18 h后表现出阳性结果的P-A瓶经常在ECMUG管中立即传代培养,孵育6 h后可确认含有总大肠菌,粪便大肠菌或大肠杆菌。因此,总孵育时间仅为24小时。(摘要以250字截断)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号