Optimum method for administration of biosynthetic human growth hormone: a randomised crossover trial of an Auto Injector and a pen injection system.

机译:人体生物合成生长激素的最佳给药方法:自动注射器和笔式注射系统的随机交叉试验。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The use of optimum conventional growth hormone administration, using a growth hormone vial combined with an Auto Injector, was compared with a pen injection system using a cartridge of growth hormone. In both methods of administration the concentration of growth hormone was 16 IU/ml. Thirty patients (22 boys, eight girls) who had all previously been treated with growth hormone (4 IU/ml) administered using needles and syringes (without an Auto Injector) were randomised into receiving one of either treatment for three months and then crossed over for a further three months. Fourteen patients (10 boys, four girls) initially received KabiVial 16 IU/ml combined with an Auto Injector while 16 patients (12 boys, four girls) were treated with KabiPen 16 IU/ml. Mean age in both groups was 9.6 years. The majority of patients in both groups were treated with a regimen of either 15 or 20 units/m2/week as a daily subcutaneous injection. Of the 30 patients who started in this trial, two who commenced using an Auto Injector refused to change to a pen system and were excluded from further analysis. When scored on a scale of -5 to +5 general convenience when changing from an Auto Injector to the KabiPen decreased from +4.7 to +1.0. When assessed for pain, the Auto Injector group scored +4.7, which decreased to -0.2 (more painful) for the pen. At the end of the trial 23 patients (82%) chose to continue with the KabiVial/Auto Injector combination as they found this less painful and the child did not see the needle or need to insert the needle manually. Five patients (18%) continued with the KabiPen as they considered the device smaller and easier to use. The accuracy of dosing using KabiVial was 100% compared with the range of 88% to 111% using KabiPen as the latter was available only in 0.5 unit increments. No growth hormone was wasted using KabiVial, although a mean of 0.6 units was wasted with every 16 IU cartridge in the KabiPen system. It is concluded that patients should be able to contribute to the choice of growth hormone delivery systems and that newer methods need careful assessment.
机译:将使用生长激素小瓶和自动注射器的最佳常规生长激素给药方法与使用生长激素药筒的笔式注射系统进行了比较。在两种给药方法中,生长激素的浓度均为16 IU / ml。将30例以前全部使用过生长激素(4 IU / ml)的患者使用针头和注射器(不使用自动注射器)进行治疗的患者(22名男孩,8名女孩)随机分入任一治疗方案三个月,然后进行交叉计算再三个月。最初接受KabiVial 16 IU / ml联合自动注射器治疗的14名患者(10名男孩,4名女孩),而使用KabiPen 16 IU / ml的16名患者(12名男孩,4名女孩)接受了治疗。两组的平均年龄均为9.6岁。两组中的大多数患者每天皮下注射15或20单位/平方米/周的方案。在该试验的30位患者中,有2位开始使用自动注射器的患者拒绝更换笔系统,因此被排除在进一步分析之外。从自动注射器更改为KabiPen时,从-5到+5的一般便利评分从+4.7降至+1.0。在评估疼痛时,“自动注射器”组的得分为+4.7,该笔下降到-0.2(更痛苦)。在试验结束时,有23位患者(82%)选择继续使用KabiVial / Auto Injector组合,因为他们发现这种疼痛减轻了,孩子没有看到针头或需要手动插入针头。五名患者(18%)继续使用KabiPen,因为他们认为该设备较小且易于使用。与使用KabiPen的88%至111%的范围相比,使用KabiVial进行计量的准确性为100%,因为后者只能以0.5单位的增量获得。使用KabiVial不会浪费生长激素,尽管在KabiPen系统中每16 IU弹药筒平均浪费0.6单位。结论是,患者应该能够为生长激素递送系统的选择做出贡献,并且新方法需要仔细评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号