The aim of this study was to determine the correlation of ultrasonographic estimates of testicular volume with true testicular volume and to compare the accuracy and precision of the three most commonly utilized formulas. A total of 15 patients underwent high-resolution ultrasonography (US) analysis for testicular volume before orchiectomy. Testicular volume was calculated using three common formulas: (1) length (L) × width (W) × height (H) × 0.52; (2) the empirical formula of Lambert: L × W × H × 0.71; and (3) L × W2 × 0.52. The actual volume of each removed testis was estimated directly by a water displacement method. Thus, four volume measurements were obtained for each of the 30 testes. The obtained data were analyzed by paired t-test and linear regression analysis. All three US formula measurements significantly underestimated the true testicular volume. The largest mean biases were observed with US formula 1, which underestimated the true volume by 3.3 mL (31%). US formula 2 had a smaller mean difference from the true volume, with an underestimation of only 0.6 mL (6%). Regression analysis showed that formulas 1 and 2 had better R2 values than formula 3. However, all three US formulas displayed a strong linear relationship with the true volume (R2= 0.872−0.977; P < 0.001). Among the commonly used US formulas, the empirical formula of Lambert (L × W × H × 0.71) provided better accuracy than the other two formulas evaluated, and better precision than formula 3. Therefore, the formula of Lambert is the optimal choice in clinical practice.
机译:这项研究的目的是确定超声检查睾丸体积与真实睾丸体积的相关性,并比较三种最常用公式的准确性和精密度。总共有15例患者在睾丸切除术前接受了高分辨率超声(US)睾丸体积分析。使用三个常用公式计算睾丸体积:(1)长(L)×宽(W)×高(H)×0.52; (2)Lambert的经验公式:L×W×H×0.71; (3)L×W 2 ×0.52。通过水置换法直接估计每个切除的睾丸的实际体积。因此,对于30个睾丸中的每一个,获得了四个体积测量值。通过配对t检验和线性回归分析对获得的数据进行分析。所有三个US公式的测量值都大大低估了睾丸的真实体积。使用美国公式1观察到最大的平均偏差,该公式低估了真实体积3.3毫升(31%)。美国配方2与真实体积的平均差较小,仅低估了0.6 mL(6%)。回归分析显示,公式1和2具有比公式3更好的R 2 值。但是,所有三个US公式都显示出与真实体积的强线性关系(R 2 = 0.872-0.977; P <0.001)。在常用的美国公式中,Lambert的经验公式(L×W×H×0.71)提供的准确性优于其他两个评估公式,并且优于公式3。因此,Lambert公式是临床上的最佳选择实践。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号