首页> 美国卫生研究院文献>Journal of Orthopaedic Surgery and Research >Review of the role of dynamic 18F-NaF PET in diagnosing and distinguishing between septic and aseptic loosening in hip prosthesis
【2h】

Review of the role of dynamic 18F-NaF PET in diagnosing and distinguishing between septic and aseptic loosening in hip prosthesis

机译:回顾性分析18F-NaF动态PET在髋关节假体中感染性和无菌性松弛的诊断和区分中的作用

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Joint replacements may fail due to infection, dislocation, peri-prosthetic fracture and loosening. Between 0.4 and 4% of joint replacements are known to be complicated by infection and aseptic loosening 2–18%. Differentiating between infection and aseptic loosening has an important bearing on the ongoing strategy for antimicrobial therapy and surgical intervention, but distinguishing one from the other can be difficult and will often require a battery of clinical and biochemical tests including the use of varying radiological modalities to accurately identify whether problematic joints are infected or aseptically loose. Prompt diagnosis is important due to the development of a biofilm on the surface of the infected prosthesis, which makes treatment difficult. There is no consensus among experts on the ideal imaging technique nor the methodology for image interpretation, but there is an increasing trend to apply hybrid imaging in the investigation of painful joint prosthesis and recent attempts have been made using PET-CT to identify aseptic loosening and infection with 18F-fluorodeoxyglucose (FDG) and sodium fluoride 18F-Na. The aim of this paper is to evaluate the role of 18F-NaF sodium fluoride (18F-NaF) positron emission tomography (PET) in distinguishing between septic and aseptic failure in hip and knee replacements, in addition to evaluating the feasibility of using multi-sequential 18F-NaF PET-CT for the assessment of painful lower limb prostheses.
机译:关节置换可能由于感染,脱位,假体周围骨折和松弛而失败。已知有0.4%至4%的关节置换术会因感染和无菌性松动而复杂化,占2-18%。区分感染和无菌性松动与正在进行的抗微生物治疗和外科手术策略有重要关系,但要区分彼此可能很困难,并且通常需要一系列临床和生化测试,包括使用各种放射学方法来准确确定有问题的关节是否被感染或无菌松动。由于受感染假体表面会形成生物膜,因此及时诊断非常重要,这使治疗变得困难。专家们对理想的成像技术或图像解释的方法尚无共识,但将混合成像技术用于关节假体疼痛的研究越来越多,并且最近已尝试使用PET-CT来识别无菌性松动和感染 18 F-氟脱氧葡萄糖(FDG)和氟化钠 18 F-Na。本文旨在评估 18 F-NaF氟化钠( 18 F-NaF)正电子发射断层显像(PET)在区分败血症和无菌衰竭方面的作用在髋关节和膝关节置换术中,除了评估使用多序列 18 F-NaF PET-CT评估下肢疼痛假体的可行性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号