BackgroundDue to potential interference of nanoparticles on bacterial quantification, there is a challenge to develop a fast, accurate and reproducible method for bacterial quantification. Currently various bacterial quantification methods are used by researchers performing nanoparticles study, but there has been no efficacy evaluation of these methods. Here we study interference of nanoparticles on three most commonly used conventional bacterial quantification methods, including colony counting to determine the colony-forming units (CFU), spectrophotometer method of optical density (OD) measurement, and flow cytometry (FCM).
机译:背景技术由于纳米颗粒对细菌定量的潜在干扰,开发一种快速,准确和可重现的细菌定量方法存在挑战。当前,进行纳米颗粒研究的研究人员使用了各种细菌定量方法,但是尚未对这些方法进行功效评估。在这里,我们研究了三种最常用的常规细菌定量方法对纳米颗粒的干扰,这些方法包括用于确定菌落形成单位(CFU)的菌落计数,光密度(OD)测量的分光光度计方法以及流式细胞术(FCM)。