首页> 美国卫生研究院文献>The Journal of Physiology >Vesicle pool partitioning influences presynaptic diversity and weighting in rat hippocampal synapses
【2h】

Vesicle pool partitioning influences presynaptic diversity and weighting in rat hippocampal synapses

机译:囊泡池分配影响大鼠海马突触的突触前多样性和权重。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Hippocampal synapses display a range of release probabilities. This is partially the result of scaling of release probability with the total number of releasable vesicles at each synapse. We have compared synaptic release and vesicle pool sizes across a large number of hippocampal synapses using FM 1-43 and confocal fluorescence microscopy. We found that the relationship between the number of recycling vesicles at a synapse and its release probability is dependent on firing frequency. During firing at 10 Hz, the release probability of each synapse is closely related to the number of recycling vesicles that it contains. In contrast, during firing at 1 Hz, different synapses turn over their recycling vesicle pools at different rates leading to an indirect relationship between recycling vesicle pool size and release probability. Hence two synapses may release vesicles at markedly different rates during low frequency firing, even if they contain similar numbers of vesicles. Both further kinetic analyses and manipulation of the number of vesicles in the readily releasable pool using phorbol ester treatment suggested that this imprecise scaling observed during firing at 1 Hz resulted from synapse-to-synapse differences in the proportion of recycling vesicles partitioned into the readily releasable pool. Hence differential partitioning between vesicle pools affects presynaptic weighting in a frequency-dependent manner. Since hippocampal single unit firing rates shift between 1 Hz and 10 Hz regimes with behavioural state, differential partitioning may be a mechanism for encoding information in hippocampal circuits.
机译:海马突触显示出一系列的释放概率。这部分是释放概率与每个突触处可释放囊泡总数的比例缩放的结果。我们已经比较了使用FM 1-43和共聚焦荧光显微镜观察的大量海马突触的突触释放和囊泡池大小。我们发现,突触中回收囊泡的数量与其释放概率之间的关系取决于发射频率。在以10 Hz的频率发射期间,每个突触的释放概率与其包含的再循环囊泡的数量密切相关。相反,在以1 Hz的频率发射期间,不同的突触以不同的速率翻转其回收囊泡池,从而导致回收囊泡池大小与释放概率之间存在间接关系。因此,即使低频突触中包含相似数量的囊泡,两个突触也可能以明显不同的速率释放囊泡。进一步的动力学分析和使用佛波酯处理的易释放池中囊泡数量的操纵均表明,以1 Hz发射时观察到的这种不精确的缩放是由于突触到突触之间分配到易释放的再循环囊泡比例上的差异引起的。池。因此,囊泡池之间的差异分配以频率依赖的方式影响突触前加权。由于海马单个单位的放电率在行为状态下在1 Hz和10 Hz的范围内变化,因此差分分配可能是在海马回路中编码信息的机制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号