We conducted a randomized clinical trial to compare periacetabular bone density changes after total hip arthroplasty using press-fit components with soft and hard liner materials. Bone density changes were assessed using quantitative computed tomography-assisted osteodensitometry. Twenty press-fit cups with alumina ceramic liners and 20 press-fit cups with highly cross-linked polyethylene liners were included; the nonoperated contralateral side was used as the control. Computed tomography scans were performed postoperatively and 1 year after the index operation. At the 1-year followup, we found no differences of periacetabular bone density changes between the alumina and polyethylene liner cohorts. However, we observed marked periacetabular cancellous bone density loss (up to −34%) in both cohorts. In contrast, we observed only moderate cortical bone density changes. The decrease of periacetabular cancellous bone density with retention of cortical bone density after THA suggests stress transfer to the cortical bone.
机译:我们进行了一项随机临床试验,以比较使用硬质和硬质衬里材料的压入配合部件进行全髋关节置换术后髋臼周围骨密度的变化。使用定量计算机断层扫描辅助骨密度测定法评估骨密度变化。其中包括20个带有氧化铝陶瓷衬里的压配合杯和20个带有高度交联聚乙烯衬里的压配合杯。非手术对侧作为对照。术后和索引手术后1年进行计算机断层扫描。在1年的随访中,我们发现氧化铝和聚乙烯衬里队列之间的髋臼周围骨密度变化没有差异。但是,我们在两个队列中均观察到了明显的髋臼周围松质骨密度损失(高达-34%)。相反,我们仅观察到了中等程度的皮质骨密度变化。 THA后髋臼松质骨密度降低并保留皮质骨密度提示应力转移至皮质骨。