AIM: To determine the optimal generator settings for endobiliary radiofrequency ablation.METHODS: Endobiliary radiofrequency ablation was performed in live swine on the ampulla of Vater, the common bile duct and in the hepatic parenchyma. Radiofrequency ablation time, “effect”, and power were allowed to vary. The animals were sacrificed two hours after the procedure. Histopathological assessment of the depth of the thermal lesions was performed.RESULTS: Twenty-five radiofrequency bursts were applied in three swine. In the ampulla of Vater (n = 3), necrosis of the duodenal wall was observed starting with an effect set at 8, power output set at 10 W, and a 30 s shot duration, whereas superficial mucosal damage of up to 350 μm in depth was recorded for an effect set at 8, power output set at 6 W and a 30 s shot duration. In the common bile duct (n = 4), a 1070 μm, safe and efficient ablation was obtained for an effect set at 8, a power output of 8 W, and an ablation time of 30 s. Within the hepatic parenchyma (n = 18), the depth of tissue damage varied from 1620 μm (effect = 8, power = 10 W, ablation time = 15 s) to 4480 μm (effect = 8, power = 8 W, ablation time = 90 s).CONCLUSION: The duration of the catheter application appeared to be the most important parameter influencing the depth of the thermal injury during endobiliary radiofrequency ablation. In healthy swine, the currently recommended settings of the generator may induce severe, supratherapeutic tissue damage in the biliary tree, especially in the high-risk area of the ampulla of Vater.
机译:目的:确定用于射频消融的最佳发生器设置。方法:射频消融是在Vater壶腹,总胆管和肝实质中的活猪中进行的。允许射频消融时间,“效果”和功率发生变化。手术后两个小时处死动物。结果:对三头猪进行了二十五次射频突射。在Vater壶腹(n = 3)中,观察到十二指肠壁坏死,其效应设定为8,功率输出设定为10 W,射影持续时间为30 s,而在12 d内表面黏膜损伤高达350μm。记录设置为8的效果的深度,设置为6 W的功率输出和30 s的拍摄持续时间。在胆总管(n = 4)中,将效果设置为8,输出功率为8 W,消融时间为30 s,可获得1070μm安全有效的消融效果。在肝实质内(n = 18),组织损伤的深度从1620μm(效果= 8,功率= 10 W,消融时间= 15 s)到4480μm(效果= 8,功率= 8 W,消融时间)不等= 90 s)。结论:导管应用的时间似乎是影响胆道射频消融过程中热损伤深度的最重要参数。在健康的猪中,当前推荐的发生器设置可能会在胆道树中引起严重的治疗性组织损伤,特别是在Vater壶腹高危区域。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号