首页> 美国卫生研究院文献>Trauma Case Reports >Transection of the anterior tibial artery during minimally invasive plate osteosynthesis of the proximal tibia
【2h】

Transection of the anterior tibial artery during minimally invasive plate osteosynthesis of the proximal tibia

机译:胫骨近端微创钢板固定中胫骨前动脉的横切

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Minimally invasive plate osteosynthesis (MIPO) techniques have been developed to protect the blood flow to tissues surrounding fractures and reduce the risk of non-union. Typically, MIPO involves the insertion of a plate through a small incision and fixation with percutaneously applied screws targeted fluoroscopically. Here we present a case of a transected anterior tibial artery during routine minimally invasive plate osteosynthesis of a tibial plateau fracture to highlight a rare complication of this type of surgery and discuss relevant anatomical considerations.
机译:已开发出微创钢板固定技术(MIPO),以保护流向骨折周围组织的血流并降低发生骨不连的风险。通常,MIPO涉及通过小切口插入板并用经荧光镜检查的经皮应用螺钉固定。在这里,我们介绍了胫骨平台骨折的常规微创钢板固定术中胫骨前动脉横断的情况,以突出这种手术的罕见并发症,并讨论了相关的解剖学考虑。