首页> 美国卫生研究院文献>Journal of Visualized Experiments : JoVE >Foodborne Pathogen Screening Using Magneto-fluorescent Nanosensor: Rapid Detection of E. Coli O157:H7
【2h】

Foodborne Pathogen Screening Using Magneto-fluorescent Nanosensor: Rapid Detection of E. Coli O157:H7

机译:使用磁荧光纳米传感器筛选食源性病原体:快速检测大肠杆菌O157:H7

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Enterohemorrhagic Escherichia coli O157:H7 has been linked to both waterborne and foodborne illnesses, and remains a threat despite the food- and water-screening methods used currently. While conventional bacterial detection methods, such as polymerase chain reaction (PCR) and enzyme-linked immunosorbent assays (ELISA) can specifically detect pathogenic contaminants, they require extensive sample preparation and lengthy waiting periods. In addition, these practices demand sophisticated laboratory instruments and settings, and must be executed by trained professionals. Herein, a protocol is proposed for a simpler diagnostic technique that features the unique combination of magnetic and fluorescent parameters in a nanoparticle-based platform. The proposed multiparametric magneto-fluorescent nanosensors (MFnS) can detect E. coli O157:H7 contamination with as little as 1 colony-forming unit present in solution within less than 1 h. Furthermore, the ability of MFnS to remain highly functional in complex media such as milk and lake water has been verified. Additional specificity assays were also used to demonstrate the ability of MFnS to only detect the specific target bacteria, even in the presence of similar bacterial species. The pairing of magnetic and fluorescent modalities allows for the detection and quantification of pathogen contamination in a wide range of concentrations, exhibiting its high performance in both early- and late-stage contamination detection. The effectiveness, affordability, and portability of the MFnS make them an ideal candidate for point-of-care screening for bacterial contaminants in a wide range of settings, from aquatic reservoirs to commercially packaged foods.
机译:肠出血性大肠杆菌O157:H7与水传疾病和食源性疾病都有联系,尽管目前使用的是食物和水的筛查方法,但仍构成威胁。尽管常规的细菌检测方法,例如聚合酶链反应(PCR)和酶联免疫吸附测定(ELISA)可以特异性检测病原体污染物,但它们需要大量的样品制备和漫长的等待时间。另外,这些做法需要复杂的实验室仪器和设置,并且必须由经过培训的专业人员执行。在此,提出了一种用于更简单诊断技术的协议,该协议的特征是在基于纳米粒子的平台中磁和荧光参数的独特组合。所提出的多参数磁荧光纳米传感器(MFnS)可以在不到1小时的时间内检测到溶液中存在的菌落形成单位少至1个,从而检测到O157:H7大肠杆菌。此外,已经证实了MFnS在复杂介质(如牛奶和湖水)中保持高度功能的能力。还使用其他的特异性测定法来证明MFnS仅在存在相似细菌种类的情况下也能够检测特定目标细菌的能力。磁模式和荧光模式的配对可以检测和定量各种浓度的病原体污染,在早期和后期污染检测中均表现出很高的性能。 MFnS的有效性,可负担性和便携性使其成为从水生水库到商业包装食品的各种环境中进行细菌污染物现场检查的理想选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号