首页> 美国卫生研究院文献>Journal of Visualized Experiments : JoVE >Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
【2h】

Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns

机译:使用反应流高效液相色谱柱进行柱后衍生

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A protocol for the use of reaction flow high performance liquid chromatography columns for methods employing post column derivatization (PCD) is presented. A major difficulty in adapting PCD to modern HPLC systems and columns is the need for large volume reaction coils that enable reagent mixing and then the derivatization reaction to take place. This large post column dead volume leads to band broadening, which results in a loss of observed separation efficiency and indeed detection in sensitivity. In reaction flow post column derivatization (RF-PCD) the derivatization reagent(s) are pumped against the flow of mobile phase into either one or two of the outer ports of the reaction flow column where it is mixed with column effluent inside a frit housed within the column end fitting. This technique allows for more efficient mixing of the column effluent and derivatization reagent(s) meaning that the volume of the reaction loops can be minimized or even eliminated altogether. It has been found that RF-PCD methods perform better than conventional PCD methods in terms of observed separation efficiency and signal to noise ratio. A further advantage of RF-PCD techniques is the ability to monitor effluent coming from the central port in its underivatized state. RF-PCD has currently been trialed on a relatively small range of post column reactions, however, there is currently no reason to suggest that RF-PCD could not be adapted to any existing one or two component (as long as both reagents are added at the same time) post column derivatization reaction.
机译:提出了使用反应流高效液相色谱柱进行柱后衍生化(PCD)方法的方案。使PCD适应现代HPLC系统和色谱柱的主要困难是需要大体积的反应盘管,以使试剂混合,然后进行衍生化反应。较大的柱后死体积会导致谱带变宽,从而导致观察到的分离效率下降,甚至导致灵敏度检测失败。在柱后衍生化反应流(RF-PCD)中,将衍生化试剂逆着流动相泵入反应流柱的一个或两个外部端口中,在此处与柱状流出物混合,并容纳在内部的玻璃料中在色谱柱末端接头内。该技术可以使柱流出物和衍生化试剂更有效地混合,这意味着可以将反应回路的体积降至最低,甚至完全消除。已经发现,就观察到的分离效率和信噪比而言,RF-PCD方法比常规PCD方法表现更好。 RF-PCD技术的另一个优点是能够监控未饱和状态下来自中央端口的废水。 RF-PCD目前已经在相对较小的柱后反应范围内进行了试验,但是,目前没有理由表明RF-PCD无法适应任何现有的一种或两种组分(只要两种试剂都在同时)柱后衍生化反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号