In this work, we reported the application and validation of an improved high-performance liquid chromatography method coupled with a fluorimetric detector (HPLC-FL) to screen the activity of two heterocyclic derivatives reported as serine palmitoyl transferase (SPT) inhibitors. The analytical conditions were optimized in terms of the derivatization procedure, chromatographic condition, extraction procedure, and method validation according to EMEA guidelines. Once fully optimized, the method was applied to assess the SPT-inhibitory activity of the above-mentioned derivatives and of the reference inhibitor myriocin. The obtained results, expressed as a percentage of residual SPT activity, were compared to those obtained with the reference radio immune assay (RIA). The good correlation between the two types of assay demonstrated that the improved HPLC-FL method is suitable for a preliminary and rapid screening of potential SPT-inhibitors.
机译:在这项工作中,我们报告了一种改进的高效液相色谱方法与荧光检测器(HPLC-FL)结合的应用和验证,该方法可以筛查报道为丝氨酸棕榈酰转移酶(SPT)抑制剂的两种杂环衍生物的活性。根据欧洲,中东和非洲(EMEA)准则,在衍生化程序,色谱条件,提取程序和方法验证方面对分析条件进行了优化。一旦完全优化,该方法就可用于评估上述衍生物和参考抑制剂myriocin的SPT抑制活性。将获得的结果(以残余SPT活性的百分比表示)与参考放射免疫测定(RIA)获得的结果进行比较。两种检测方法之间的良好相关性表明,改进的HPLC-FL方法适用于初步和快速筛选潜在的SPT抑制剂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号