首页> 美国卫生研究院文献>Membranes >An Efficient Polymer Inclusion Membrane-Based Device for Cd Monitoring in Seawater
【2h】

An Efficient Polymer Inclusion Membrane-Based Device for Cd Monitoring in Seawater

机译:一种用于海水中镉监测的高效聚合物包膜膜装置

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A novel and simple device that includes a polymer inclusion membrane (PIM) has been prepared and tested for the first time to detect low concentration levels of cadmium in seawater. The ionic liquid trihexyl (tetradecyl) phosphonium chloride (THTDPCl) has been shown to be an effective extractant when incorporated in a PIM that uses cellulose triacetate (CTA) as a polymer. However, it has been reported that the use of a plasticizer is mandatory to ensure an effective transport, which uses both ultrapure water and a nitric acid solution as a stripping phase. A special device incorporating a PIM made of 50% CTA, 40% nitrophenyl octyl ether (as a plasticizer), and 10% THTDPCl, effectively allows the quantitative transport and preconcentration of 10 µg L−1 Cd from seawater samples to a stripping phase consisting of 0.5 M HNO3 solution. This study shows that the efficiency of the PIM system is not affected by high salinity nor the presence of large amounts of other ions, and can thus facilitate Cd monitoring in seawater samples.
机译:已经准备并首次测试了一种新颖且简单的设备,该设备包括一个聚合物包含膜(PIM),用于检测海水中低浓度的镉。当将离子液体三己基(十四烷基)氯化nium(THTDPC1)掺入使用三乙酸纤维素(CTA)作为聚合物的PIM中时,已显示是有效的萃取剂。但是,据报道必须使用增塑剂以确保有效运输,该运输使用超纯水和硝酸溶液作为汽提相。包含PIM的特殊设备,该PIM由50%CTA,40%硝基苯基辛基醚(作为增塑剂)和10%THTDPCl制成,可以有效地定量输送和预浓缩10 µg L -1 Cd海水样品到由0.5 M HNO3溶液组成的汽提阶段。这项研究表明,PIM系统的效率不受高盐度或大量其他离子的存在的影响,因此可以促进海水样品中Cd的监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号