We examined the precision, accuracy, and capability of detecting changes of Dual-Energy X-ray Absorptiometry (DXA) for the measurements of total-body weight (TBW), total-body fat weight (TBFW), and total-body lean weight (TBLW) in an 8-week follow-up study of rats. Twenty male rats (4-week) were divided into 2 diet groups. For 8 weeks, we measured body composition (TBW, TBFW, TBLW) by DXA and TBW by an electronic scale once a week. In week 8, we measured body composition 5 times by DXA and TBFW by dissecting experiment (EXP) of euthanized rats (12-week). Total-body fat ratio (TBFR) was defined as TBFW/(TBFW+TBLW). The precision of DXA was evaluated by measuring the coefficient of variation (CV) and accuracy was evaluated by comparing DXA-derived data with EXP data. The capability of detecting changes of DXA in follow-up study was verified by analyzing the trend of DXA-derived values over the 8 weeks. For TBW, TBFW, TBLW of DXA, CVs were 0.02 ± 0.01, 0.10 ± 0.05, 0.03 ± 0.02 and errors were − 6.996 ± 3.429 (r = 0.999), + 14.729 ± 3.663 (r = 0.982), − 21.725 ± 4.223 (r = 0.991), respectively. Prediction models were [EXP TBW = − 31.767 + 1.085 (DXA TBW), R2 = 0.998, root mean square error (RMSE) = 1.842] and [EXP TBFR = − 0.056 + 1.177 (DXA TBFR), R2 = 0.948, RMSE = 0.007]. Over 8 weeks, DXA TBW and DXA TBLW steadily increased, DXA TBFW steadily increased followed by saturation or declination, difference of DXA TBFW between 2 diet groups steadily increased. In conclusion, our study verified that DXA (iNSiGHT VET DXA, OsteoSys, Korea) is accurate and precise enough to measure body composition of rats. Additionally, we confirmed the possibility that DXA could be used for the long-term follow-up studies.
机译:我们检查了双能量X射线吸收仪(DXA)的变化的精度,准确性和检测能力,以测量总体重(TBW),总脂肪体重(TBFW)和总瘦体重(TBLW)在一项为期8周的大鼠追踪研究中。将20只雄性大鼠(4周)分为2个饮食组。在8周的时间里,我们每周用电子秤通过DXA和TBW测量身体成分(TBW,TBFW,TBLW)。在第8周,我们通过剖析安乐死大鼠的实验(EXP)(12周),通过DXA和TBFW测量了5次人体成分。全身脂肪比率(TBFR)定义为TBFW /(TBFW + TBLW)。通过测量变异系数(CV)评估DXA的精度,并通过将DXA衍生的数据与EXP数据进行比较来评估DXA的精度。通过分析8周内DXA衍生值的趋势,证实了在后续研究中检测DXA变化的能力。对于DXA的TBW,TBFW,TBLW,CV为0.02±0.01、0.10±0.05、0.03±0.02,误差为-6.996±3.429(r = 0.999),+ 14.729±3.663(r = 0.982),− 21.725±4.223( r = 0.991)。预测模型为[EXP TBW =-31.767 + 1.085(DXA TBW),R2 = 0.998,均方根误差(RMSE)= 1.842]和[EXP TBFR =-0.056 + 1.177(DXA TBFR),R2 = 0.948,RMSE = 0.007]。在8周内,DXA TBW和DXA TBLW稳定增加,DXA TBFW稳定增加,随后达到饱和或偏斜,两个饮食组之间DXA TBFW的差异稳定增加。总而言之,我们的研究证实了DXA(iNsiGHT VET DXA,韩国OsteoSys)足够精确,可以测量大鼠的身体成分。此外,我们证实了DXA可以用于长期随访研究的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号