首页> 美国卫生研究院文献>Malaysian Orthopaedic Journal >Highly Crosslinked Polyethylene Tibial Post Fracture in the Unafflicted Limb of a Patient with Unilateral Lower Limb Poliomyelitis: A Case Report
【2h】

Highly Crosslinked Polyethylene Tibial Post Fracture in the Unafflicted Limb of a Patient with Unilateral Lower Limb Poliomyelitis: A Case Report

机译:单侧下肢脊髓灰质炎患者未患肢的高度交联聚乙烯胫骨后骨折:一例报告

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。
获取外文期刊封面目录资料

摘要

We present a unique case of tibial post fracture of a posterior-stabilised total knee arthroplasty (PS-TKA) using highly crosslinked polyethylene (HXLPE) in the unafflicted limb of a patient who had poliomyelitis. The tibial post is an upright structure perpendicular to the PE insert articular surface which articulates with the cam of the femoral component to prevent excessive posterior translation of the tibia. We explore the choice of PS polyethylene (PE) inserts in patients with neuromuscular disorders (NMD). A 74-year old gentleman presented with recurrent knee pain seven years after the index PS-TKA with HXLPE. The TKA was performed on the unafflicted left limb (contralateral to the weak side affected by poliomyelitis). The posterior drawer test was positive. During the single-stage revision surgery, the HXLPE tibial post was noted to be broken. The liner was replaced with a thicker non-HXLPE. The patient achieved an excellent outcome at one-year post-surgery. This is the first report of HXLPE tibial post fracture in the unaffected knee of a patient with NMD affecting the lower limb. The HXLPE’s reduced resistance to fatigue crack propagation might not be suitable in PS-TKA where there might be focal stress points on the tibial post, which was amplified in this case as it was the limb that the patient most depended on. When managing end-stage osteoarthritis with TKA in the unafflicted knee of a patient with NMD causing lower limb weakness, the selection of polyethylene material in PS-TKA may need more consideration than previously thought.
机译:我们介绍了一个独特的案例,在患有脊髓灰质炎的患者的未患肢中,使用高度交联的聚乙烯(HXLPE)对后路稳定的全膝关节置换术(PS-TKA)进行胫后骨折。胫骨柱是垂直于PE插入关节表面的直立结构,该结构与股骨组件的凸轮铰接,以防止胫骨过度向后平移。我们探讨了神经肌肉疾病(NMD)患者中PS聚乙烯(PE)插入物的选择。一名74岁的绅士在HXLPE指数PS-TKA七年后出现了膝关节复发性疼痛。 TKA在未患病的左肢(受脊髓灰质炎影响的弱侧对侧)上进行。后抽屉试验为阳性。在单阶段翻修手术中,HXLPE胫骨柱被发现断裂。用较厚的非HXLPE代替衬管。术后一年,患者取得了优异的疗效。这是NMD影响下肢的未患膝关节HXLPE胫骨后骨折的首次报道。 HXLPE降低的对疲劳裂纹扩展的抵抗力可能不适用于PS-TKA,因为PS-TKA可能在胫骨柱上存在焦点应力点,在这种情况下,由于患者最依赖四肢,因此这种应力放大了。在患有NMD导致下肢无力的NMD患者的未患膝关节中用TKA治疗晚期骨关节炎时,在PS-TKA中选择聚乙烯材料可能需要比以前想象的更多的考虑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号