A prospective study of 1,017 patients who received MIOM during spine surgery procedures between March 2000 and December 2005. To determine the sensitivity and specificity of MIOM techniques used to monitor spinal cord and nerve roots function during spine surgery. MIOM has become a widely used method of monitoring neural function during spine surgery. Several techniques only monitor either ascending or descending pathways and thus may not provide sensitive or specific results. MIOM aims to monitor both ascending and descending pathways therefore giving immediate feedback information regarding any neurological deficits during the operation. Intraoperative sensory spinal and cortical evoked potentials, combined with monitoring of EMG and motor evoked potentials recorded from the spinal cord and muscles elicited by electrical motor cortex, spinal cord, cauda equina and nerve root stimulation, was evaluated and compared with post-operative clinical neurological changes. One thousand and seventeen consecutive patients underwent a total of 4,731 h of MIOM to evaluate any neural deficits that may have occurred during spine surgery. Of these, 935 were true negative cases, 8 were false negative cases, 66 were true positive cases and 8 were false positive cases, resulting in a sensitivity of 89% and a specificity of 99%. Based on the results of this study, MIOM is an effective method of monitoring the spinal cord functional integrity during spine surgery and therefore can lead to reduction of neurological deficit and consequently improve postoperative results.
机译:对2000年3月至2005年12月在脊柱外科手术期间接受MIOM的1,017例患者进行的前瞻性研究。为了确定用于监测脊柱外科手术中脊髓和神经根功能的MIOM技术的敏感性和特异性。 MIOM已成为脊柱手术中监测神经功能的一种广泛使用的方法。几种技术仅监视上升或下降路径,因此可能无法提供敏感或特定的结果。 MIOM旨在监视上升和下降路径,因此可提供有关手术过程中任何神经功能缺损的即时反馈信息。评估术中感觉脊髓和皮层诱发电位,并结合监测肌电图和由电动皮层,脊髓,马尾神经和神经根刺激诱发的脊髓和肌肉记录的运动诱发电位,并与术后临床神经系统比较变化。连续对117例患者进行了总计4731小时的MIOM,以评估脊柱手术过程中可能发生的神经缺陷。其中,935例为真阴性病例,8例为假阴性病例,66例为真阳性病例,8例为假阳性病例,敏感性为89%,特异性为99%。基于这项研究的结果,MIOM是监测脊柱手术过程中脊髓功能完整性的有效方法,因此可以减少神经功能缺损,从而改善术后效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号