首页> 美国卫生研究院文献>Frontiers in Oncology >Comparison of Skull Motions in Six Degrees of Freedom Between Two Head Supports During Frameless Radiosurgery by CyberKnife
【2h】

Comparison of Skull Motions in Six Degrees of Freedom Between Two Head Supports During Frameless Radiosurgery by CyberKnife

机译:射波刀无框放射外科中两个头部支撑物在六个自由度上的头骨运动比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Introduction: Maintaining immobilization to minimize skull motion is important during frameless radiosurgery. This study aimed to compare the intrafractional skull motions between two head supports.>Methods: With 6D skull tracking system, 4,075 image records from 45 patients receiving radiosurgery by CyberKnife were obtained. Twenty-three patients used TIMO head supports (CIVCO) (Group A) and twenty-two patients used Silverman head supports (CIVCO) with MoldCare cushions (ALCARE) (Group B). The skull motions in X (superior-inferior), Y (right-left), Z (anterior-posterior) axes, 3D (three-dimensional) vector, Roll, Pitch and Yaw between the two groups were compared and the margins of planning target volume were estimated.>Results: The translational motions in Group A were similar in three axes at initial but became different after 10 min, and those in Group B were less prominent in the Y axis. The rotational errors in Group A were most obvious in Yaw, but those in Group B were stationary in three axes. The motions in the X axis, 3D vector, Pitch and Yaw in Group B were significantly smaller than those in Group A; conversely, the motions in the Z axis in Group B were larger. To cover the 95% confidence intervals, margins of 0.77, 0.79, and 0.40 mm in the X, Y, and Z axes, respectively, were needed in Group A, and 0.69, 0.50, and 0.51 mm were needed in Group B.>Conclusions: Both head supports could provide good immobilization during the frameless radiosurgery. Silverman head support with MoldCare cushion was better than TIMO head support in the superior-inferior direction, 3D vector, Pitch and Yaw axes, but worse in the anterior-posterior direction.
机译:>简介:在无框放射外科手术期间,保持固定状态以最大程度地减少颅骨运动很重要。这项研究旨在比较两个头枕之间的颅骨内运动。>方法:通过6D颅骨跟踪系统,从45例使用射波刀接受放射外科手术的患者中获得了4,075个图像记录。 23例患者使用TIMO头枕(CIVCO)(A组),22例患者使用Silverman头枕(CIVCO)并带有MoldCare靠垫(ALCARE)(B组)。比较两组在X(上下),Y(左右),Z(前后),3D(三维)向量,横滚,俯仰和偏航的头骨运动,并比较计划的余量>结果: A组的平移运动最初在三个轴上相似,但在10分钟后变得不同,而B组的平移运动在Y轴上不太明显。在偏航中,A组的旋转误差最明显,而B组的旋转误差在三个轴上是固定的。 B组的X轴,3D矢量,俯仰和偏航运动明显小于A组;相反,B组在Z轴上的运动较大。为了覆盖95%的置信区间,A组分别需要在X,Y和Z轴上的边距分别为0.77、0.79和0.40 mm,B组分别需要分别为0.69、0.50和0.51 mm的边距。 strong>结论:在无框放射外科手术中,两个头部支架都可以提供良好的固定效果。在上下方向,3D矢量,俯仰和偏航轴上,带有MoldCare垫的Silverman头部支撑比TIMO头部支撑要好,但在前后方向上则较差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号