首页> 美国卫生研究院文献>Frontiers in Public Health >Assessing Exposures to Magnetic Resonance Imaging’s Complex Mixture of Magnetic Fields for In Vivo In Vitro and Epidemiologic Studies of Health Effects for Staff and Patients
【2h】

Assessing Exposures to Magnetic Resonance Imaging’s Complex Mixture of Magnetic Fields for In Vivo In Vitro and Epidemiologic Studies of Health Effects for Staff and Patients

机译:评估磁共振成像复杂磁场混合物的暴露量以进行体内体外和对员工和患者健康影响的流行病学研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

A complex mixture of electromagnetic fields is used in magnetic resonance imaging (MRI): static, low-frequency, and radio frequency magnetic fields. Commonly, the static magnetic field ranges from one to three Tesla. The low-frequency field can reach several millitesla and with a time derivative of the order of some Tesla per second. The radiofrequency (RF) field has a magnitude in the microtesla range giving rise to specific absorption rate values of a few Watts per kilogram. Very little attention has been paid to the case where there is a combined exposure to several different fields at the same time. Some studies have shown genotoxic effects in cells after exposure to an MRI scan while others have not demonstrated any effects. A typical MRI exam includes muliple imaging sequences of varying length and intensity, to produce different types of images. Each sequence is designed with a particular purpose in mind, so one sequence can, for example, be optimized for clearly showing fat water contrast, while another is optimized for high-resolution detail. It is of the utmost importance that future experimental studies give a thorough description of the exposure they are using, and not just a statement such as “An ordinary MRI sequence was used.” Even if the sequence is specified, it can differ substantially between manufacturers on, e.g., RF pulse height, width, and duty cycle. In the latest SCENIHR opinion, it is stated that there is very little information regarding the health effects of occupational exposure to MRI fields, and long-term prospective or retrospective cohort studies on workers are recommended as a high priority. They also state that MRI is increasingly used in pediatric diagnostic imaging, and a cohort study into the effects of MRI exposure on children is recommended as a high priority. For the exposure assessment in epidemiological studies, there is a clear difference between patients and staff and further work is needed on this. Studies that explore the possible differences between MRI scan sequences and compare them in terms of exposure level are warranted.
机译:磁共振成像(MRI)中使用电磁场的复杂混合物:静态,低频和射频磁场。通常,静磁场的范围是一到三个特斯拉。低频场可以达到几毫特斯拉,时间导数约为每秒特斯拉。射频(RF)场的大小在微特斯拉范围内,从而导致每公斤几瓦的比吸收率值。很少同时关注同时暴露于多个不同领域的情况。一些研究表明,暴露于MRI扫描后对细胞具有遗传毒性作用,而其他研究则未显示任何作用。典型的MRI检查包括长度和强度不同的多重成像序列,以产生不同类型的图像。每个序列的设计都考虑到了特定的目的,因此,例如,可以优化一个序列以清楚地显示出脂肪水的对比度,而另一个序列可以针对高分辨率细节进行优化。至关重要的是,未来的实验研究必须对所使用的暴露物进行详尽的描述,而不仅仅是“使用普通的MRI序列”这样的说法。即使指定了顺序,制造商之间在RF脉冲高度,宽度和占空比等方面也可能有很大不同。 SCENIHR的最新意见指出,关于职业性接触MRI场对健康的影响的信息很少,因此建议将对工人的长期前瞻性或回顾性队列研究作为优先事项。他们还指出,MRI在儿科诊断成像中越来越多地被使用,并且推荐将MRI暴露对儿童的影响进行队列研究作为优先事项。对于流行病学研究中的暴露评估,患者和医务人员之间存在明显差异,需要对此进行进一步的工作。有必要探索MRI扫描序列之间可能存在的差异,并根据暴露水平进行比较的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号