Matrix metalloproteinase‑1 and microRNA‑486‑5p in urinary exosomes can be used to detect early lung cancer: A preliminary report

机译:尿外泌体中的基质金属蛋白酶-1 和 microRNA-486-5p 可用于检测早期肺癌:初步报告

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study describes a novel molecular-genetic method suitable for lung cancer (LC) screening in the work-place and at community health centers. Using urinary-isolated exosomes from 35 patients with LC and 40 healthy volunteers, the expression ratio of MMP-1/CD63, and the relative expression levels of both microRNA (miRNA)-21 and miRNA-486-5p were measured. MMP-1/CD63 expression ratio was significantly higher in patients with LC than in the healthy controls {1.342 [95% confidence interval (CI): 0.890–1.974] vs. 0.600 (0.490–0.900); P<0.0001}. The relative expression of miRNA-486-5p in male healthy controls was significantly different from that in female healthy controls, whereas there was no significant difference in miRNA-21. Receiver operating characteristic curve (ROC) analysis of MMP-1/CD63 showed 92.5% sensitivity and 54.3% specificity, whereas miRNA-486-5p showed 85% sensitivity and 70.8% specificity for men, and 70.0% sensitivity and 72.7% specificity for women. The logistic regression model used to evaluate the association of LC with the combination of MMP-1/CD63 and miRNA-486-5p revealed that the area under the ROC curve was 0.954 (95% CI: 0.908–1.000), and the model had 89% sensitivity and 88% specificity after adjusting for age, sex and smoking status. These data suggested that the combined analysis of MMP-1/CD63 and miRNA-486-5p in urinary exosomes may be used to detect patients with early-stage LC in the work-place and at community health centers, although confirmational studies are warranted.
机译:本研究描述了一种适用于工作场所和社区卫生中心肺癌 (LC) 筛查的新型分子遗传学方法。使用 35 例 LC 患者和 40 例健康志愿者的尿液分离外泌体,测量 MMP-1/CD63 的表达比值,以及 microRNA (miRNA)-21 和 miRNA-486-5p 的相对表达水平。LC 患者的 MMP-1/CD63 表达比显著高于健康对照 {1.342 [95% 置信区间 (CI):0.890–1.974] vs. 0.600 (0.490–0.900);P<0.0001}。男性健康对照中 miRNA-486-5p 的相对表达与女性健康对照相比差异显著,而 miRNA-21 的相对表达无显著差异。MMP-1/CD63 的受试者工作特征曲线 (ROC) 分析显示敏感性为 92.5% 和 54.3%,而 miRNA-486-5p 对男性的敏感性为 85%,特异性为 70.8%,对女性的敏感性为 70.0% 和 72.7%。用于评估 LC 与 MMP-1/CD63 和 miRNA-486-5p 联合治疗的相关性的 logistic 回归模型显示,ROC 曲线下面积为 0.954 (95% CI: 0.908–1.000),调整年龄、性别和吸烟状况后,模型具有 89% 的敏感性和 88% 的特异性。这些数据表明,尿液外泌体中 MMP-1/CD63 和 miRNA-486-5p 的联合分析可用于检测工作场所和社区卫生中心的早期 LC 患者,尽管需要进行验证研究。

著录项

代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号