摘要

A study concerning the flexural behavior of glass beams reinforced with steel fibers is presented in this paper. Two types of steel fibers were used for reinforcement, made of high strength and stainless steel. The coupling effect of the two materials was studied in terms of energy dissipation and failure loads, by comparing the elastic limits and the post-elastic behaviors of the reinforced glass beams. Results demonstrated that it is possible to increase the overall structural safety of a steel fiber reinforced glass beam. The relationship between the bending force and deflections was initially linear, however, following the opening of first cracks in the glass, the reinforcement steel material was able to withstand the tensile stresses, governing the overall post-elastic phase.
机译:本文对钢纤维增强的玻璃梁的抗弯性能进行了研究。两种类型的钢纤维用于增强,分别由高强度和不锈钢制成。通过比较增强玻璃梁的弹性极限和后弹性行为,从能量耗散和破坏载荷的角度研究了两种材料的耦合效应。结果表明,可以提高钢纤维增强玻璃梁的整体结构安全性。弯曲力和挠度之间的关系最初是线性的,但是,在玻璃中出现第一个裂纹之后,钢筋材料能够承受拉伸应力,从而控制了整个后弹性阶段。