首页> 美国卫生研究院文献>Clinical Molecular Pathology >A comparison of IgG anti-rubella activity in frozen serum stored in primary gel separation tubes or secondary tubes
【2h】

A comparison of IgG anti-rubella activity in frozen serum stored in primary gel separation tubes or secondary tubes

机译:初级凝胶分离管或二级管中保存的冷冻血清中IgG抗风疹活性的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Aims: To determine the suitability of primary gel separation tubes for the storage of frozen sera intended for serological testing.>Methods: Blood samples from 102 patients were collected into gel separation tubes. The sera from these samples were split between the primary gel separation tubes and conventional plastic storage tubes and frozen. A year later, the tubes were thawed and anti-rubella IgG concentrations were compared for the serum pairs using the Wilcoxon signed rank test.>Results: No significant difference was detected between the two storage methods.>Conclusions: Frozen storage of serum samples in primary gel separation tubes is a practical alternative to storing separated sera in secondary containers. Adopting this practice has advantages for laboratories in reducing specimen handling and reducing errors in labelling stored samples.
机译:>目的::确定主要的凝胶分离管是否适合用于血清学测试的冷冻血清的存储。>方法:将102位患者的血液样本收集到凝胶分离管中。将这些样品中的血清在一级凝胶分离管和常规塑料储存管之间分开并冷冻。一年后,将管解冻,并使用Wilcoxon符号秩和检验比较血清对的抗风疹IgG浓度。>结果:两种存储方法之间均未发现明显差异。>结论:将血清样品冷冻储存在一级凝胶分离管中是一种替代方法,可将分离的血清储存在二级容器中。对于实验室而言,采用这种做法在减少样品处理和减少标记存储样品的错误方面具有优势。