首页> 美国卫生研究院文献>Canadian Medical Association Journal >The late results of cardiac valve replacement using autologous fascia lata
【2h】

The late results of cardiac valve replacement using autologous fascia lata

机译:自体筋膜置换术心脏瓣膜置换术的最新结果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Over an eight-month period beginning in November 1969, 53 patients received 63 fascia lata heart valves at the Toronto General Hospital. The late results of this form of valve substitution are reviewed. The fascia used to fashion the tricuspid valve underwent progressive thickening and contracture and this process caused failure of the prosthesis within months of insertion. The mitral fascial prosthesis failed in a similar manner although the process took longer. The aortic fascia lata valve, however, has not shown progressive thickening after 3½ years and it has so far retained its functional integrity. Indeed, we have been impressed by the excellent clinical results and absence of complications such as thromboembolism although anticoagulation has not been used. We therefore consider that fascia lata valves offer a suitable alternative to other forms of aortic valve substitution, but are unsatisfactory for tricuspid or mitral valve replacement.
机译:从1969年11月开始的8个月中,有53位患者在多伦多总医院接受了63根筋膜的心脏瓣膜手术。回顾了这种瓣膜置换的最新结果。用于塑造三尖瓣的筋膜进行性增厚和挛缩,该过程导致假体在插入后数月内失效。尽管该过程花费了更长的时间,但是二尖瓣筋膜假体也以类似的方式失败了。然而,主动脉筋膜瓣瓣膜在3½年后仍未显示出逐渐增厚,并且迄今为止仍保持其功能完整性。的确,尽管未使用抗凝治疗,但出色的临床结果和不存在诸如血栓栓塞等并发症给我们留下了深刻的印象。因此,我们认为筋膜瓣​​瓣膜瓣膜瓣替代其他形式的主动脉瓣膜瓣膜是合适的替代方法,但对于三尖瓣或二尖瓣瓣膜瓣膜瓣置换术仍不令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号