Quantitative three dimensional echocardiography in patients with pulmonary hypertension and compressed left ventricles: comparison with cross sectional echocardiography and magnetic resonance imaging.

机译:肺动脉高压和左心室受压患者的三维三维超声心动图:与截面超声心动图和磁共振成像的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

OBJECTIVE: To evaluate the accuracy of quantitative three dimensional echocardiography in patients with deformed left ventricles. DESIGN: Three dimensional and cross sectional echocardiographic estimates of left ventricular volume and ejection fraction were prospectively compared to those obtained from magnetic resonance imaging. SETTING: Echocardiography laboratory of a university hospital. PATIENTS: 26 patients (9 months to 42 years, median age 11 years) with pulmonary hypertension and fixed reversal of normal interventricular septal curvature. MAIN OUTCOME MEASURES: Left ventricular end diastolic and end systolic volumes and ejection fraction. RESULTS: Three dimensional echocardiographic comparison to magnetic resonance imaging (MRI) yielded r values of 0.94 and 0.87 with a bias of -6.9 (SD 6.9) ml and -16 (11.2) ml for systolic and diastolic volumes respectively. Inter-observer variability was minimal (8.3% and 7.6% respectively). Cross sectional echocardiography gave correlation coefficients of 0.62 and 0.80 and bias of 3.1 (14.1) ml and 16.3 (18.3) ml for systolic and diastolic volumes respectively. Ejection fraction by three dimensional echocardiography also had closer agreement with MRI (bias = 1.1 (7.7)%) than cross sectional echocardiography (bias = 4.4 (13.9)%). CONCLUSIONS: Three dimensional echocardiography provides reliable estimates of left ventricular volumes and ejection fraction, comparable to magnetic resonance imaging in pulmonary hypertension patients with compressed ventricular geometry. Because it eliminates the need for geometric assumptions it shows closer agreement with magnetic resonance imaging in that setting than cross sectional echocardiography.
机译:目的:探讨定量三维超声心动图检查对畸形左心室患者的准确性。设计:前瞻性比较了左心室容积和射血分数的三维和横断面超声心动图估计值与磁共振成像获得的估计值。单位:大学医院的超声心动图实验室。患者:26例(9个月至42岁,中位年龄11岁)患有肺动脉高压并固定逆转正常的室间隔间隔曲度。主要观察指标:左心室舒张末期和收缩末期容积及射血分数。结果:三维超声心动图与磁共振成像(MRI)的比较得出r值为0.94和0.87,收缩压和舒张压的偏差分别为-6.9(SD 6.9)ml和-16(11.2)ml。观察者之间的差异很小(分别为8.3%和7.6%)。横截面超声心动图的收缩压和舒张压相关系数分别为0.62和0.80,偏差分别为3.1(14.1)ml和16.3(18.3)ml。三维超声心动图的射血分数与MRI的一致性(偏倚= 1.1(7.7)%)也比截面超声心动图(偏倚= 4.4(13.9)%)更接近。结论:三维超声心动图可提供可靠的左心室容积和射血分数的估计值,与磁共振成像在压缩性心室几何形状的肺动脉高压患者中相当。因为它不需要几何假设,所以与横截面超声心动图相比,在这种情况下显示出与磁共振成像更接近的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号