您现在的位置:首页>美国卫生研究院文献>Biomicrofluidics

期刊信息

  • 期刊名称:

    -

  • 刊频: Quarterly
  • NLM标题: Biomicrofluidics
  • iso缩写: -
  • ISSN: -

年度选择

更多>>

  • 排序:
  • 显示:
  • 每页:
全选(0
<1/20>
1456条结果
  • 机译 芯片上的大脑:发展历史和未来展望
    摘要:Since the advent of organ-on-a-chip, many researchers have tried to mimic the physiology of human tissue on an engineered platform. In the case of brain tissue, structural connections and cell–cell interactions are important factors for brain function. The recent development of brain-on-a-chip is an effort to mimic those structural and functional aspects of brain tissue within a miniaturized engineered platform. From this perspective, we provide an overview of trace of brain-on-a-chip development, especially in terms of complexity and high-content/high-throughput screening capabilities, and future perspectives on more in vivo-like brain-on-a-chip development.
  • 机译 一种开放式微型设备,可提高神经元轴突转运分析的荧光标记的质量
    摘要:Abnormal axonal transport of vesicles as well as organelles in a particular set of neurons is implicated in the pathogenesis of many neurodegenerative diseases such as amyotrophic lateral sclerosis, Alzheimer's disease, and Parkinson's disease. Although various types of microfluidic multicompartmental devices with closed microchannels have been recently developed and widely used for axonal transport analysis, most of the existing devices are troublesome and time-consuming to handle, such as culture maintenances, sample collections, and immunocytochemistry. In this study, we overcome such inherent shortcomings by developing a novel open-type device that enables easy cell maintenance and sample collections. In our device, microgrooves instead of microchannels were directly fabricated on a glass substrate, thereby making possible a high-resolution optical observation. Compared with the conventional closed-type devices, our newly designed device allowed us to efficiently and precisely label the axonal acidic vesicles by fluorescent dyes, facilitating a high-throughput analysis of axonal vesicular transport. The present novel device, as a user-friendly and powerful tool, can be implemented in molecular and cellular pathogenesis studies on neurological diseases.
  • 机译 通过微流系统中质膜的拓扑重新连接,实现同种异体细胞之间的核移植
    摘要:Previous studies have demonstrated that somatic cells fused with pluripotent stem cells can be reprogrammed on the basis of reprogramming factors acquired from the latter. However, fusion-reprogrammed cells are deemed unsuitable for therapeutic applications mainly because conventional fusion techniques often yield tetraploid fusants that contain exogenous genes acquired from the fusion partners. Here, we present a novel cell–cell topological reconnection technique and demonstrate its application to nuclear transplantation between a somatic cell and a stem cell without nuclei mixing. As a proof of concept, a microfluidic fusion chip embodied with a microslit (4 μm in width) to prevent nuclei mixing was developed and used to perform one-to-one electrofusion of a target somatic cell (Jurkat cell) with an induced pluripotent stem (iPS) cell. To extract its cytoplasm, the target cell was first topologically connected to a sacrificial iPS cell by electrofusion via a microslit, followed by shear flow removal of the latter to obtain a cytoplasm-depleted nucleus of the target cell. Then, to replace the lost cytoplasm, topological reconnection to a second iPS cell was performed similarly by electrofusion, followed by shear flow separation of the target cell to enable it acquire most of the iPS cytoplasm, but without nuclei mixing. Microscopic observation of target cells harvested and cultured post hoc in a microwell confirmed that they manifested cell division. Taken together, these results demonstrate the potential application of the cell–cell topological reconnection technique to somatic cell nuclear transplantation for the generation of autologous pluripotent stem cells.
  • 机译 2018年裁判鸣谢
    • 作者:Leslie Y. Yeo
    • 刊名:Biomicrofluidics
    • 2019年第1期
    摘要:
  • 机译 将微流体和纳米流体社区纳入未来十年
    • 作者:Leslie Y. Yeo
    • 刊名:Biomicrofluidics
    • 2019年第1期
    摘要:
  • 机译 固态纳米孔的流体动力学和传输
    摘要:The resistive pulse method based on measuring the ion current trace as a biomolecule passing through a nanopore has become an important tool in biotechnology for characterizing molecules. A detailed physical understanding of the translocation process is essential if one is to extract the relevant molecular properties from the current signal. In this Perspective, we review some recent progress in our understanding of hydrodynamic flow and transport through nanometer sized pores. We assume that the problems of interest can be addressed through the use of the continuum version of the equations of hydrodynamic and ion transport. Thus, our discussion is restricted to pores of diameter greater than about ten nanometers: such pores are usually synthetic. We address the fundamental nanopore hydrodynamics and ion transport mechanisms and review the wealth of observed phenomena due to these mechanisms. We also suggest future ionic circuits that can be synthesized from different ionic modules based on these phenomena and their applications.
  • 机译 通过更改支架结构减少输尿管支架内结垢的沉积:基于微流体的研究
    摘要:Ureteric stents are clinically deployed to retain ureteral patency in the presence of an obstruction of the ureter lumen. Despite the fact that multiple stent designs have been researched in recent years, encrustation and biofilm-associated infections remain significant complications of ureteral stenting, potentially leading to the functional failure of the stent. It has been suggested that “inactive” side-holes of stents may act as anchoring sites for encrusting crystals, as they are associated with low wall shear stress (WSS) levels. Obstruction of side-holes due to encrustation is particularly detrimental to the function of the stent, since holes provide a path for urine to by-pass the occlusion. Therefore, there is an unmet need to develop novel stents to reduce deposition of encrusting particles at side-holes. In this study, we employed a stent-on-chip microfluidic model of the stented and occluded ureter to investigate the effect of stent architecture on WSS distribution and encrustation over its surface. Variations in the stent geometry encompassed (i) the wall thickness and (ii) the shape of side-holes. Stent thickness was varied in the range 0.3-0.7 mm, while streamlined side-holes of triangular shape were evaluated (with a vertex angle in the range 45°-120°). Reducing the thickness of the stent increased WSS and thus reduced the encrustation rate at side-holes. A further improvement in performance was achieved by using side-holes with a triangular shape; notably, a 45° vertex angle showed superior performance compared to other angles investigated, resulting in a significant increase in WSS within “inactive” side-holes. In conclusion, combining the optimal stent thickness (0.3 mm) and hole vertex angle (45°) resulted in a ∼90% reduction in encrustation rate within side-holes, compared to a standard design. If translated to a full-scale ureteric stent, this optimised architecture has the potential for significantly increasing the stent lifetime while reducing clinical complications.
  • 机译 社论:告别生物微流体技术的创立者和主编
    摘要:
  • 机译 出版者注:``低温流动光刻''[Biomicrofluidics 12,054105(2018)]
    摘要:
  • 机译 基于细胞的分子诊断的微流体方法
    摘要:The search for next-generation biomarkers has enabled cell-based diagnostics in a number of disciplines ranging from oncology to pharmacogenetics. However, cell-based diagnostics are still far from clinical reality due to the complex assays and associated protocols which typically require cell isolation, lysis, DNA extraction, amplification, and detection steps. Leveraging recent advances in microfluidics, many biochemical assays have been translated onto microfluidic platforms. We have compared and summarized recent advances in modular approaches toward the realization of fully-integrated, cell-based molecular diagnostics for clinical and point-of-care applications.
  • 机译 评论文章:体外捕获大脑神经血管单元的生理复杂性
    摘要:With the accelerating pace of brain research in recent years and the growing appreciation of the complexity of the brain and several brain-associated neurological diseases, the demand for powerful tools to enhance drug screening, diagnosis, and fundamental research is greater than ever. Highly representative models of the central nervous system (CNS) can play a critical role in meeting these needs. Unfortunately, in vivo animal models lack controllability, are difficult to monitor, and do not model human-specific brain behavior accurately. On the other hand, in silico computational models struggle to capture comprehensively the intertwined biological, chemical, electrical, and mechanical complexity of the brain. This leaves us with the promising domain of “organ-on-chip” in vitro models. In this review, we describe some of the most pioneering efforts in this expanding field, offering a perspective on the new possibilities as well as the limitations of each approach. We focus particularly on how the models reproduce the blood–brain barrier (BBB), which mediates mass transport to and from brain tissue. We also offer a brief commentary on strategies for evaluating the blood–brain barrier functionality of these in vitro models, including trans-endothelial electrical resistance (TEER), immunocytochemistry, and permeability analysis. From the early membrane-based models of the BBB that have grown into the Transwell® class of devices, to the era of microfluidic chips and a future of bio-printed tissue, we see enormous improvement in the reliability of in vitro models. More and more of the biological and structural complexity of the BBB is being captured by microfluidic chips, and the organ-specificity of bio-printed tissue is also significantly improved. Although we believe that the long-term solution will eventually take the form of automated and parallelized bio-printing systems, we find that valuable transport studies can already be accomplished with microfluidic platforms.
  • 机译 基于形状的液相分离微米/纳米颗粒
    摘要:The production of particles with shape-specific properties is reliant upon the separation of micro-/nanoparticles of particular shapes from particle mixtures of similar volumes. However, compared to a large number of size-based particle separation methods, shape-based separation methods have not been adequately explored. We review various up-to-date approaches to shape-based separation of rigid micro-/nanoparticles in liquid phases including size exclusion chromatography, field flow fractionation, deterministic lateral displacement, inertial focusing, electrophoresis, magnetophoresis, self-assembly precipitation, and centrifugation. We discuss separation mechanisms by classifying them as either changes in surface interactions or extensions of size-based separation. The latter includes geometric restrictions and shape-dependent transport properties.
  • 机译 使用液体等分和虹吸抽空技术的基于磁盘的酶联免疫吸附测定
    摘要:A cost-effective way to carry out multiple enzyme-linked immunosorbent assays (ELISAs) on a centrifugal platform using the liquid-aliquoting and siphoning-evacuation (LASE) technique was developed in this paper. Instead of preloading all the reagents in the reservoirs before testing, each reagent was loaded only one time during testing. The reagent was distributed into equal aliquots and delivered into reaction chambers by the aliquoting fluidic function. In addition, a siphoning-evacuation technique was developed to improve the washing efficiency and simplify the assay protocol. Furthermore, the entire assay protocol can be conducted using a two-step spinning protocol, which greatly reduces the cost of the motor control system. With the LASE technique, a low-cost and user-friendly ELISA system can be achieved.
  • 机译 将无细胞蛋白质合成和纯化整合到一个微流控芯片中,以按需生产重组蛋白质
    摘要:Recombinant proteins have shown several benefits compared with their non-recombinant counterparts in protein therapeutics. However, there are still some problems with the storage and distribution of recombinant proteins, owing to their temperature sensitivity. Microfluidic chips can integrate different functional modules into a single device because of the advantages of integration and miniaturization, which have the special potential to synthesize drugs when and where they are needed most. Here, we integrated cell-free protein synthesis and purification into a microfluidic chip for the production of recombinant protein. The chip consisted of a main channel and a branch channel. The main channel included two pinches, which were filled with template DNA-modified agarose microbeads and nickel ion-modified agarose beads as the cell-free protein synthesis unit and protein purification unit, respectively. The reaction mixture for protein synthesis was introduced into the main channel and first passed through the protein synthesis unit where the target protein was synthesized; next, the reaction mixture passed through the protein purification unit where the target protein was captured; and, finally, pure protein was collected at the outlet when washing buffer and eluting buffer were sequentially introduced into the branch channel. Enhanced green fluorescent protein (EGFP) was used as the model to investigate the performance of our chip. One chip could produce 70 μl of EGFP solution (144.3 μg/ml, 10.1 μg) per batch, and another round of protein synthesis and purification could be performed after replacing or regenerating nickel ion-modified agarose beads. It should be possible to produce other recombinant proteins on demand with this chip by simply replacing the template DNA.
  • 机译 集成的微流控平台,用于大小选择性地捕获血液中单核细胞
    摘要:Reliable separation and isolation of target single cells from bodily fluids with high purity is of great significance for an accurate and quantitative understanding of the cellular heterogeneity. Here, we describe a fully integrated single-blood-cell analysis platform capable of size-selective cell separation from a population containing a wide distribution of sizes such as diluted blood sample and highly efficient entrapment of single monocytes. The spiked single U937 cells (human monocyte cell line) are separated in sequence by two different-sized microfilters for removing large cell clumps, white blood cells, and red blood cells and then discriminated by dielectrophoretic force and isolated individually by downstream single-cell trapping arrays. When 2% hematocrit blood cells with a final ratio of 1:1000 U937 cells were introduced under the flow rate of 0.2 ml/h, 400 U937 cells were trapped sequentially and deterministically within 40 s with single-cell occupancy of up to 85%. As a proof-of-concept, we also demonstrated single monocyte isolation from diluted blood using the integrated microfluidic device. This size-selective, label-free, and live-cell enrichment microfluidic single blood-cell isolation platform for the processing of cancer and blood cells has a myriad of applications in areas such as single-cell genetic analysis, stem cell biology, point-of-care diagnostics, and cancer diagnostics.
  • 机译 低温流动光刻
    摘要:Flow lithography (FL) is a microfluidic technique distinguished for its ability to produce hydrogel microparticles of various geometrical and chemical designs. While FL is typically performed in room temperature, this paper reports a new technique called low temperature flow lithography that uses low synthesis temperature to increase the degree of polymerization of microparticles without compromising other aspects of flow lithography. We suggest that decreased oxygen diffusivity in low temperature is responsible for the increase in polymerization. Microparticles that exhibit a higher degree of polymerization display a more developed polymer network, ultimately resulting in a more defined morphology, higher incorporation of materials of interest, and improved functional performance. This work demonstrates the increase in the degree of polymerization by examining the temperature effect on both the physical and chemical structures of particles. We show applications of this technique in synthesizing thin microparticles and enhancing microparticle-based detection of microRNA. Low temperature FL offers a simple and easy method of improving the degree of polymerization, which can be implemented in a wide range of FL applications.
  • 机译 片上口腔粘膜评估细菌和牙科材料对层的特异性反应
    摘要:The human oral mucosa hosts a diverse microbiome and is exposed to potentially toxic biomaterials from dental restoratives. Mucosal health is partly determined by cell and tissue responses to challenges such as dental materials and pathogenic bacteria. An in vitro model to rapidly determine potential layer-specific responses would lead to a better understanding of mucosal homeostasis and pathology. Therefore, this study aimed to develop a co-cultured microfluidic mucosal model on-a-chip to rapidly assess mucosal remodeling and the responses of epithelial and subepithelial layers to challenges typically found in the oral environment. A gingival fibroblast-laden collagen hydrogel was assembled in the central channel of a three-channel microfluidic chamber with interconnecting pores, followed by a keratinocyte layer attached to the collagen exposed in the pores. This configuration produced apical and subepithelial side channels capable of sustaining flow. Keratinocyte, fibroblast, and collagen densities were optimized to create a co-culture tissue-like construct stable over one week. Cells were stained and imaged with epifluorescence microscopy to confirm layer characteristics. As proof-of-concept, the mucosal construct was exposed separately to a dental monomer, 2-hydroxylethyl methacrylate (HEMA), and the oral bacteria Streptococcus mutans. Exposure to HEMA lowered mucosal cell viability, while exposure to the bacteria lowered trans-epithelial electrical resistance. These findings suggest that the oral mucosa-on-a-chip is useful for studying oral mucosal interactions with bacteria and biomaterials with a histology-like view of the tissue layers.
  • 机译 带有气动垂直纳米限制的小型流通池,用于单分子成像和操作
    摘要:Convex Lens-induced Confinement (CLiC) is a single-molecule imaging technique that uses a deformable glass flow cell to gently trap, manipulate, and visualize single molecules within micro- and nano-structures, to enable a wide range of applications. Here, we miniaturize the CLiC flow cell, from 25 × 25 to 3 × 3 mm2 and introduce pneumatic control of the confinement. Miniaturization of the flow cell improves fabrication throughput by almost two orders of magnitude and, advantageous for pharmaceutical and diagnostic applications where samples are precious, significantly lowers the internal volume from microliters to nanoliters. Pneumatic control of the device reduces the confinement gradient and improves mechanical stability while maintaining low autofluorescence and refractive index-matching with oil-immersion objectives. To demonstrate our “mini CLiC” system, we confine and image DNA in sub-50 nm nanogrooves, with high DNA extension consistent with the Odijk confinement regime.
  • 机译 通过使用组织样本快速筛选癌症亲和试剂的微流体平台
    摘要:Cancer is the most serious disease worldwide, and ovarian cancer (OvCa) is the second most common type of gynecological cancer. There is consequently an urgent need for early-stage detection of OvCa, which requires affinity reagent biomarkers for OvCa. Systematic evolution of ligands by exponential enrichment (SELEX) and phage display technology are two powerful technologies for identifying affinity reagent biomarkers. However, the benchtop protocols for both screening technologies are relatively lengthy and require well-trained personnel. We therefore developed a novel, integrated microfluidic system capable of automating SELEX and phage display technology. Instead of using cancer cell lines, it is the first work which used tissue slides as screening targets, which possess more complicated and uncovered information for affinity reagents to recognize. This allowed for the identification of aptamer (nucleic acid) and peptide probes specific to OvCa cells and tissues. Furthermore, this developed system could be readily modified to uncover affinity reagents for diagnostics or even target therapy of other cancer cell types in the future.
  • 机译 流体剪切应力引起的微流控装置中细胞变形的生物物理分析
    摘要:Even though the majority of breast cancers respond well to primary therapy, a large percentage of patients relapse with metastatic disease, for which there is no treatment. In metastasis, a tumor sheds a small number of cancerous cells, termed circulating tumor cells (CTCs), into the local vasculature, from where they spread throughout the body to form new tumors. As CTCs move through the circulatory system, they experience physiological forces not present in the initial tumor environment, namely, fluid shear stress (FSS). Evidence suggests that CTCs respond to FSS by adopting a more aggressive phenotype; however, to date single-cell morphological changes have not been quantified to support this observation. Furthermore, the methodology of previous studies involves inducing FSS by flowing cells through the tubing, which lacks a precise and tunable control of FSS. Here, a microfluidic approach is used for isolating and characterizing the biophysical response of single breast cancer cells to conditions experienced in the circulatory system during metastasis. To evaluate the single-cell response of multiple breast cancer types, two model circulating tumor cell lines, MDA-MB-231 and MCF7, were challenged with FSS at precise magnitudes and durations. As expected, both MDA-MB-231 and MCF7 cells exhibited greater deformability due to increasing duration and magnitudes of FSS. However, wide variations in single-cell responses were observed. MCF7 cells were found to rapidly deform but reach a threshold value after 5 min of FSS, while MDA-MB-231 cells were observed to deform at a slower rate but with a larger threshold of deformation. This behavioral diversity suggests the presence of distinct cell subpopulations with different phenotypes.

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号