首页> 外文期刊>世界针灸杂志(英文版) >温和灸感传体温度和灸距关系的研究
【24h】

温和灸感传体温度和灸距关系的研究

机译:温和灸感传体温度和灸距关系的研究

获取原文
获取原文并翻译 | 示例
       

摘要

Objective To explore the relationship between the receptor temperature and moxibustion distance of mild moxibustion,and provide evidence for clinical moxibustion distance.Methods Mild moxibustion was carried out for 15min by adopting moxibustion shelf,and the moxibustion ash was shook off automatically for once every 3 min.The distance between moxa stick and temperature sensor was set as 2 cm,3 cm,4 cm and 5 cm,respectively,by ruler.The temperature was recorded for once every 2 s with photothermal detection system for moxibustion combustion to form a temperature profile.The initial temperature,maximum temperature and average temperature were observed,and the experimental data were analyzed via SPSS18.0 statistical software.Results The initial receptor temperature was (25.33±0.29) ℃when the moxibustion distance was 2 cm,(25.29±0.05) ℃ when the moxibustion distance was 3 cm,(25.43±0.17) ℃ when the moxibustion distance was 4cm,and (25.16±0.22) ℃ when the moxibustion distance was 5 cm,respectively.The maximum temperature was (74.96±1.20) ℃ when the moxibustion distance was 2 cm,(51.70±0.74) ℃ when the moxibustion distance was 3 cm,(49.33±0.40) ℃ when the moxibustion distance was 4 cm,and (42.50±0.26) ℃ when the moxibustion distance was 5 cm,respectively.The average temperature was (62.40±7.84) ℃-(62.68±7.58) ℃ when the moxibustion distance was 2 cm,(44.77±3.31) ℃-(45.11±3.21) ℃ when the moxibustion distance was 3 cm,(42.72±-3.86) ℃-(43.12±3.54) ℃ when the moxibustion distance was 4 cm,and (38.45±1.67) ℃-(38.50±1.63) ℃ when the moxibustion distance was 5 cm,respectively.The temperature curve showed that the fluctuation range was the maximum when the moxibustion distance was 2 cm,larger when the moxibustion distance was 3 cm,smaller when the moxibustion distance was 4 cm,and minimum when the moxibustion distance was 5 cm.There was no significant difference in the initial temperature of mild moxibustion at different distances,however,the maximum temperature,average temperature and the fluctuation range of temperature curve were closely related to the moxibustion distance.Conclusion The nearer the distance is,the higher the maximum temperature and average temperature as well as the larger the fluctuation range will be,and the farther the distance is,the lower the maximum temperature and average temperature as well as the smaller the fluctuation range will be.According to preliminary analysis,the temperature will be the most suitable when the moxibustion distance is 3 cm-4 cm.%目的:探讨温和灸灸温与灸距之间的关系,为临床施灸距离提供参数.方法:运用艾灸架实施温和灸15分钟,每3分钟自动抖灰一次,通过直尺设置艾条与温度传感器之间的施灸距离分别为2 cm、3 cm、4 cm和5 cm,采用艾灸燃烧光热检测系统每2s记录一次温度值,制成温度曲线图,观察其初始温度、最高温度及平均温度,实验数据由SPSS18.0统计分析.结果:初始温度,灸距2 cm时25.33±0.29℃,灸距3 cm时(25.29±0.05)℃,灸距4cm时(25.43±0.17)℃,灸距5 cm时(25.16±0.22)℃;最高温度,灸距2 cm时(74.96±1.20)℃,灸距3 cm时(51.70±0.74)℃,灸距4 cm时(49.33±0.40)℃,灸-5 cm时(42.50±0.26)℃;平均温度,灸距2 cm时(62.40±7.84)℃-(62.68±7.58)℃,灸距3 cm时(44.77±3.31)℃-(45.11±3.21)℃,灸距4 cm时(42.72±3.86)℃-(43.12±3.54)℃,灸距5 cm时(38.45±1.67)℃-(38.50±1.63)℃.温度曲线显示,灸距2 cm时波幅最大,灸距3 cm时波幅较大,灸距4 cm时波幅较小,灸距5 cm时波幅最小.不同距离温和灸初始温度无明显差异,而最高温度、平均温度及温度曲线波幅与距离关系密切.结论:距离越近最高温度及平均温度越高、波幅越大,距离越远最高温度及平均温度越低、波幅越小,初步分析灸距在3 cm-4 cm时温度最为适合.
机译:目的探讨受体温度与轻度艾灸的艾灸距离之间的关系,为临床迁徙距离提供证据。通过采用艾灸架进行15min的方法,每3分钟自动震动一次艾灸灰烬。Moxa棒和温度传感器之间的距离分别通过尺寸设定为2cm,3cm,4cm和5cm,每2秒记录一次,每2秒用光热检测系统进行一次,用于艾灸燃烧,形成温度曲线。初始温度,最高温度和平均温度观察,通过SPSS18.0统计软件分析了实验数据。结果初始受体温度(25.33±0.29)℃±2cm,(25.29±0.05当艾灸距离为3厘米时℃,当艾灸距离为4厘米时(25.43±0.17)℃,(25.16±0.22)℃,艾灸距离为5厘米,REAC当艾灸距离为2厘米时,最高温度(74.96±1.20)℃(51.70±0.74)℃,(51.70±0.74),当艾灸距离为4厘米时(49.33±0.40)℃,和(当艾灸距离为5厘米时42.50±0.26)℃分别为5厘米(62.40±7.84)℃(62.68±7.58)℃,当艾灸距离为2厘米时(44.77±3.31)℃ - (45.11± 3.21)℃时,艾灸距离为3厘米,(42.72±3.86)℃ - (43.12±3.54)℃时,艾灸距离为4厘米,(38.45±1.67)℃ - (38.50±1.63)℃时,艾灸时距离分别为5厘米。温度曲线表明,当艾灸距离为3厘米时,波动范围是最大值,当艾灸距离为4厘米时,更大的距离为4厘米,当艾灸距离时最小5厘米。然而,不同距离在不同距离下的初始温度没有显着差异,但最高温度,平均温度温度和温度曲线的波动范围与艾灸距离密切相关。结论距离越近,最高温度和平均温度越高,波动范围越大,距离越远,降低最高温度和平均温度以及波动范围越小。根据初步分析,当艾灸距离为3cm-4厘米时,温度将是最合适的。%目:探讨探讨和灸灸温与灸距之间的相关,为临床临床施灸距离偏分。方法:使用艾灸架实施温和灸15分类,每3分类自动抖灰,通讯直尺设置艾条与温度仪之间的施灸距离分别为止2厘米,3厘米,4厘米和5厘米,使用艾灸燃烧光热系统每2s记录一次温度值,制成温度曲的图,观察观察温度温度,最高温度及平衡温度,实验数由spss18.0统计分子。结果:初始温度,灸距2 cm时25.33±0.29℃,3厘米时(25.29±0.05)℃,灸距4cm时(25.43±0.17)℃,灸距5cm时(25.16±0.22 )℃;最高温度,灸距2 cm时(74.96±1.20)℃,灸距3cm时(51.70±0.74)℃,灸距4cm时(49.33±0.40)℃,灸-5 cm时(42.50± 0.26)℃;平面温度,灸距2 cm时(62.40±7.84)℃ - (62.68±7.58)℃,灸距3cm时(44.77±3.31)℃ - (45.11±3.21)℃,¼4厘米时(42.72±3.86)℃ - (43.12±3.54)℃,灸距5cm时(38.45±1.67)℃ - (38.50± 1.63)℃。温度温度曲显示,灸距2 cm时波幅最大,灸距3 cm时波幅较大,灸距4 cm时波幅较小,灸距5 cm时波幅最小。不锈钢温和灸初始明亮差异,而最高温度,平均温度及温度曲曲波幅与距离关键词结论:距离越近最高温度及平等温度温度高,波幅越大,距离越远最高温度及平等温度低,波幅越小,初步分享在3cm-4 cm时温度温度最最为主。

著录项

  • 来源
    《世界针灸杂志(英文版)》 |2017年第4期|13-19|共7页
  • 作者单位

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    中南大学商学院;

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    上海中医药大学上海市针灸经络研究所,上海201203;

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    中南大学物理学院;

    中南大学物理学院;

    湖南中医药大学针灸推拿学院,湖南长沙410208,中国;

    上海中医药大学上海市针灸经络研究所,上海201203;

  • 收录信息 中国科学引文数据库(CSCD);
  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    温和灸; 距离; 感受器温度; 温度传感器; 艾条燃烧光热检测系统;

  • 入库时间 2022-08-18 16:37:10

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号