在定容燃烧弹中不同位置布置测量电极进行了离子电流与火焰发展的试验研究,应用AVL-FIRE 软件研究了电极附近温度和焰后区离子电流间的关系.结果表明:当采用点火电极测量时,离子电流包括点火、火焰前锋区与焰后区三个阶段;当测量电极与点火电极分开时,离子电流只有部分火焰前锋区与焰后区.不同位置测量的离子电流焰后区信号开始出现时所对应温度值均在2000K左右;随着测量电极与点火电极间距的增加,电极附近温度依次降低,离子电流焰后区信号亦逐渐降低.焰后区离子电流随着温度的升高而增加,二者基本呈线性关系.%Experiment on ionization current and flame development were investigated in a constant volume combustion bomb, and the relationship between temperature around electrodes and ionization current in post-flame zone were studied based on AVL-FIRE simulation. Results show that the current has three phases reflecting spark ignition, front-flame and post-flame when using the ignition electrodes as detecting electrode. However, when ignition electrodes and detecting electrodes are separated, the current shows two phases reflecting partial front-flame and post-flame. The current in the post-flame zone appears at the temperature about 2 000 K for different electrodes location. With the increase of the distance between ignition electrodes and detector electrodes, the current and temperature at the electrodes gap are decreased. A linear relationship between temperature and current is presented when temperature is over 2 000 K.

著录项

  • 来源
    《内燃机学报》|2011年第3期|260-264|共5页
  • 作者单位

    西安交通大学,动力工程多相流国家重点实验室,陕西,西安,710049;

    西安交通大学,动力工程多相流国家重点实验室,陕西,西安,710049;

    西安交通大学,动力工程多相流国家重点实验室,陕西,西安,710049;

    西安交通大学,动力工程多相流国家重点实验室,陕西,西安,710049;

    西安交通大学,动力工程多相流国家重点实验室,陕西,西安,710049;

    陕西工业技术研究院,陕西,西安,710054;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 理论;
  • 关键词

    电极位置; 温度; 离子电流; 燃烧; 焰后区;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号