Aiming at the complicated calculation of the current-carrying capacity of aluminum conductor alloy reinforced, a simplified method for calculating its current-carrying capacity is proposed.Firstly, the theoretical method for calculating the current-carrying capacity is studied, and the differences in current-carrying calculation are analyzed according to character-istics of aluminum conductor steel reinforced and aluminum conductor alloy reinforced.Then the simplified calculation method is proposed for the current-carrying capacity of aluminum conductor alloy reinforced, and the carrying-current capacity of an aluminum conductor alloy reinforced in different ambient temperature is calculated by the proposed simplified method.The test values are recorded and compared with the calculated values, and the reasons for the errors of simplified calculation method are analyzed.The test results show that the simplified method has small calculating work and the satisfied calculation accuracy for the engineering, which provides a reference for the current-carrying capacity analysis of aluminum conductor alloy rein-forced.%针对铝合金芯铝绞线载流量计算复杂的特点,提出了一种铝合金芯铝绞线载流量的简化算法. 首先研究了计算导线载流量的理论方法,根据钢芯铝绞线和铝合金芯铝绞线的特点分析两者在载流量计算中的差异,提出铝合金芯铝绞线载流量的简化算法,并使用该简化计算法计算了某种铝合金芯铝绞线在不同环境温度下的载流量值. 然后对该种导线进行载流量试验记录载流量实测值,对比载流量计算值与实测值,分析简化计算法产生误差的原因.试验结果表明,该简化算法计算量小且计算精度满足工程要求,为铝合金芯铝绞线载流量的分析提供参考.