首页> 中文期刊> 《石油化工》 >凝胶渗透色谱内标法测定聚合物的相对分子质量及其分布

凝胶渗透色谱内标法测定聚合物的相对分子质量及其分布

         

摘要

The internal standard method in GPC was established by adding internal standard into the analyte. In this method,in virtue of the fact that the retention time of internal standard and analyte change synchronously with the change in pump flow rate,the molecular weight was calculated after the retention time of the analyte had been transformed into relative time,which can eliminate errors caused by the instability of the instrument;and the influence of the molecular polarity and relative molecular weight of the internal standard on the calculation results was investigated. The results indicated that the deviation of the calculated result was close to the deviation of the instrument's repeatable deviation,the errors caused by the instability of the instrument can be eliminated by internal standard method. Different molecular weight and molecular polarity of the internal standard had little influence on the calculated results. The internal standard method in GPC could achieve rapid and accurate testing so as to greatly improve work efficiency,and was of very high application value in monitoring the working state of instruments.%建立了在待测试样中加入内标物的GPC内标法,该方法利用内标物和待测物保留时间的提前或延后能与泵流速变化同步的特点,将待测物保留时间转化为相对时间后再进行计算,以消除仪器不稳定带来的误差;并考察了内标物的分子极性及相对分子质量对计算结果的影响.实验结果表明,采用GPC内标法所得计算结果偏差接近仪器自身水平,可消除仪器不稳定带来的误差;GPC内标法对内标物分子极性及相对分子质量的选择没有特别要求;GPC内标法用于监测仪器的工作状态有着较高的应用价值,可实现快速精准测试,极大地提高了工作效率.

著录项

  • 来源
    《石油化工》 |2018年第3期|291-294|共4页
  • 作者

    唐正伟; 梁汉东; 徐林;

  • 作者单位

    中国矿业大学(北京) 化学与环境工程学院,北京 100083;

    中国石化 北京北化院燕山分院 橡塑新型材料合成国家工程研究中心,北京 102500;

    中国矿业大学(北京) 化学与环境工程学院,北京 100083;

    中国石化 北京北化院燕山分院 橡塑新型材料合成国家工程研究中心,北京 102500;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 取样、分析鉴定;
  • 关键词

    凝胶渗透色谱; 内标; 校准;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号