首页> 中文期刊> 《汽车安全与节能学报 》 >锂电池热管理中空气冷却效果的实验与模拟

锂电池热管理中空气冷却效果的实验与模拟

             

摘要

把空冷方法用于商业磷酸铁锂电池以分析强化传热效果。对商用磷酸铁锂电池进行15~35A的放电测试,并根据实验数据对单一电池的温度分布进行了数值模拟。分析和模拟了空气横掠2个和3个电池情况下的冷却效果。实验和模拟的结果表明:在0~30A电流放电的情况下,空气冷却对电池热管理具有积极作用。在放电电流小于30A的情况下时,电池的最大温度低于50℃,但是电池间的温差仍然高于5℃。在放电电流大于30A的情况,仅仅通过空气冷却不能使电池和电池组内温度均匀分布,即不能满足电池散热的需求。%The air-cooled methods were used for cooling commercial LiFePO4 batteries to illustrate the effect of heat transfer enhancement. The commercial LiFePO4 batteries were tested at 15-35 A. The temperature distribution in a single battery was numerical ly simulated according to the experiment al data. Air flow across two and three batteries was simulated to illustrate the air-cooled effect. Experiment al and simulation results show that air-coola has a positive significance for the battery thermal management at discharging currents of 0-30 A. For discharging currents less than 30 A, the peak temperature in batteries is less than 50 ℃, while the temperature difference between batteries is still more than 5 ℃. When the discharging current is higher than 30 A, air-cooling for batteries and battery packs can not guarantee evenly temperature distribution, not being able to meet the regui re ment of batteriy heat dissipation.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号