飞秒激光辅助 LASIK 术后早期角膜生物力学各指标的变化

         

摘要

AIM: To investigate the changes of corneal biomechanics after Femto LDV laser flapping in laser in situ keratomileusis ( LASIK) . METHODS: Preoperatively, 3 months, 6 months after LASIK, 93 myopia patients ( 186 eyes ) in flapping procedure by Femto LDV laser were examined by Ocular response analyzer (ORA).The central corneal thickness ( CCT ) was also measured by ultrasonic pachymetry. Parameters were compared between postoperative ( 3 months) and preoperative, postoperative (6 months). Comparisons included the corneal thickness and corneal compensated intraocular pressure ( Iopcc ) , Goldmann correlated IOP value ( Iopg ) , corneal resistance factor ( CRF) , corneal hysteresis ( CH) . RESULTS: The CCT ( 447.61 ±39.57μm ) were significantly changed comparing with preoperative (539.88±29.72μm) (t=-47.223;P=0.000).The CCT of 6 months postoperative ( 448.78 ±39.19μm ) was slightly thicker than that of 3 months'(t=2.15,P=0.033).Iopcc, Iopg of 3 months after LASIK (13.75±2.13, 9.54±2.35) mmHg were significantly changed comparing with preoperative (16.29±2.88, 15.09±3.29 )mmHg (t=-13.604,-23.594;P=0.000, 0.000).The difference was (2.55 ±2.25, 5.55 ± 3.21) mmHg.There were no significant changes between Iopcc, Iopg of 6 months (13.61±1.96,9.32±2.07)mmHg and that of 3 months after LASIK. CRF and CH of 3 months after LASIK (6.36±1.45,7.71±1.30)mmHg were significantly changed comparing with preoperative's (9.84±1.99,9.77±1.56)mmHg (t=-24.116, -19.171; P=0.000, 0.000).The difference was (3.49 ±1.97, 2.06 ± 1.47 ) mmHg. There were no statistical differences between 6 months (6.24 ±1.38, 7.67 ±1.25) mmHg and 3 months(t=1.456, 0.636;P=0.147, 0.525). CONCLUSION: The corneal biomechanical properties after FS-LASIK are lower than that of preoperative. Corneal biomechanics sustains steadily about 3 months after LASIK.%目的:探讨准分子激光原位角膜磨镶术( LASIK )使用Femto LDV飞秒激光制瓣近视患者的角膜生物力学各指标的变化。  方法:选取93例186眼近视患者均行飞秒激光辅助LASIK术。分别于术前;术后3,6 mo应用眼反应分析仪( ocular response analyzer , ORA )检测角膜补偿眼压( corneal compensated intraocular pressure , Iopcc )、模拟Goldmann眼压( Goldmann correlated IOP value , Iopg )、角膜阻力因子( corneal resistance factor , CRF )、角膜滞后量( corneal hysteresis ,CH)。超声角膜厚度测量。比较术后3 mo与术前,术后6 mo与术后3 mo测量值的差异。  结果:术后3 mo中央角膜平均厚度为447.61±39.57μm与术前539.88±29.72μm比较,差异有显著统计学意义( t=-47.223, P=0.000);术后6 mo 448.78±39.19μm较术后3mo厚度差异有统计学意义(t=2.15,P=0.033)。术后3 mo Iopcc , Iopg 分别为13.75±2.13,9.54±2.35 mmHg较术前16.29±2.88,15.09±3.29 mmHg显著降低(t=-13.604,-23.594;P=0.000,0.000)。 Iopcc, Iopg分别较术前降低2.55±2.25,5.55±3.21mmHg。术后6 mo 13.61±1.96,9.32±2.07 mmHg与术后3 mo比较差异无统计学意义( t=-0.977,1.447,P=0.33,0.15)。CRF,CH术后3mo测量值6.36±1.45,7.71±1.30mmHg较术前9.84±1.99,9.77±1.56mmHg显著降低(t=-24.116,-19.171;P=0.000,0.000)。 CRF,CH分别较术前降低3.49±1.97,2.06±1.47mmHg。术后6mo 6.24±1.38, ;7.67±1.25 mmHg与术后3 mo比较差异无统计学意义( t=1.456,0.636,P=0.147,0.525)。  结论:飞秒激光辅助LASIK术对角膜生物力学有显著影响,术后角膜生物力学各指标较术前显著降低。术后3 mo内生物力学各指标基本稳定。

著录项

  • 来源
    《国际眼科杂志》 |2013年第12期|2554-2556|共3页
  • 作者单位

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100062 中国北京市;

    北京茗视光眼科诊所;

    100730 中国北京市;

    首都医科大学附属北京同仁眼科中心;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类
  • 关键词

    飞秒激光; 角膜厚度; 角膜生物力学;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号