首页> 中文期刊>广州化工 >阳极溶出方波伏安法测定水体中的铜离子

阳极溶出方波伏安法测定水体中的铜离子

     

摘要

建立了阳极溶出方波伏安法测定水体中的铜离子的方法。在浓度为0.15 mol/L, pH=5.0的NH4 Cl溶液中,于-0.11 V( vs.SCE)产生Cu2+的灵敏峰,其峰高与离子浓度在0.02~2.0 mg/L范围内,呈良好的线性关系,相关系数R2=0.9992,线性方程为Y=60.2785X+0.1030,在Cu2+本底值为0.0208 mg/L水体中添加3个水平(0.02、0.04、0.10 mg/L)平均回收率在89.3%~106.5%之间,相对标准偏差(RSDs)为3.2%~9.1%(n=6),检出限(LOD)为0.005 mg/L。本方法操作简便迅速,灵敏度高,重现性好,能够满足水体中检测铜离子要求。%A method for determination of the copper ion content of the water by square wave anodic stripping voltammeter was established.In solution of 0.15 mol/L NH4 Cl at pH=5 , sensitive stripping peak of Cu (Ⅱ) was observed.The peak potential of the wave was-0.11 V ( vs.SCE) .Measured within the range of 0.02~2.0 mg/L, the mass concentration of Cu (Ⅱ) and peak height showed a good linear relationship ( R2≥0.9992 ) , linear regression equation was Y=60.2785X+0.1030.The average recovery rates were 89.3%~106.5%, and relative standard deviation (RSDs) were 3.2%~9.1%( n=6), at the spiked level 0.02, 0.04, 0.10 mg/L, in water with Cu (Ⅱ) content 0.0208 mg/L.Limit of qualitative of the method( LOD) was 0.005 mg/L.Results showed that the method was convenient operation, high sensitivity, good reproducibility, could meet determination of Cu(Ⅱ) content in water.