建立了以环己烷为萃取剂、气相色谱法(氢火焰离子化检测器,FID)测定水质样品中可萃取性石油烃(C10~ C40)的分析方法.以正构烷烃混合标准溶液为定性和定量校准标准,以色谱峰面积总和与混合标准溶液总浓度建立校准曲线进行外标法定量.方法检出限为0.01 mg/L,经验证方法精密度和准确度良好.同时,分别以气相色谱法和红外光度法测定了地表水、污水处理厂出水、海水和化工废水等实际样品,对比实验结果表明,在可萃取性石油烃C10 ~C40的碳数范围内,气相色谱法的测试结果与红外光度法无明显差异,有较好的可比性.%A method of liquid-liquid extraction and gas chromatography (flame ionization detector,FID) analysis was developed for extractable petroleum hydrocarbons C10-C40 in water.N-alkanes were used as qualitative and quantitative standards and the standard curve was established between total peak area and total concentration for external standard quantification.The detection limit of petroleum C10-C40 was 0.01 mg/L.Precision and accuracy of the method were both satisfying.Analysis results were compared between gas chromatography and infrared spectrophotometry when determining petroleum in actual samples of surface water,effluent of municipal wastewater treatment plant,seawater and chemical industry wastewater.It was found that there was no significant difference between the results of EPH C10-C40 analyzed by GC-FID and infrared spectrophotometry.Results of two methods had good comparability.

著录项

  • 来源
    《中国环境监测》 |2018年第2期|83-88|共6页
  • 作者单位

    国家环境保护二(噁)英污染控制重点实验室,国家环境分析测试中心,北京100029;

    国家环境保护二(噁)英污染控制重点实验室,国家环境分析测试中心,北京100029;

    环境保护部环境发展中心,北京100029;

    国家环境保护二(噁)英污染控制重点实验室,国家环境分析测试中心,北京100029;

    北京化工大学,北京100029;

    国家环境保护二(噁)英污染控制重点实验室,国家环境分析测试中心,北京100029;

    国家环境保护二(噁)英污染控制重点实验室,国家环境分析测试中心,北京100029;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 监测分析方法;
  • 关键词

    石油烃; 气相色谱法; 液液萃取;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号