摘要

针对现有封装结构会对灵敏度造成一定程度的损失,使现有水听器的灵敏度小于水听器芯片裸测灵敏度的问题,改用了透声性能好、耐腐蚀的丁腈橡胶( NBR)制作的透声帽,并对现有的矢量水听器的封装外壳进行相应的优化设计。该封装结构的水听器的共振频率降低到50 Hz以下,水听器所感兴趣的频段(50 Hz~4 kHz)不会受到封装谐振的干扰,拓宽了水听器的工作频段。该封装的灵敏度提高到几乎与裸片的灵敏度一致,达到(-170±2)dB,并优化金属管壳的圆盘的尺寸,即水听器最大径,由36 mm缩小至28 mm,使水听器的封装进一步小型化。%This paper introduces the material nitrile butadiene rubber ( NBR ) with good performance in sound transmission and anti-corrosion in making the sound-transparent cap,and puts forward an optimal design of the encap-sulation shell of the MEMS bionic vector hydrophone,resolving the problem that current encapsulation structure causes is to lose the sensitivity, making the hydrophone less sensitive than the bare chip. With the new encapsulation structure,the resonance frequency of the hydrophone has been dropped below 50 Hz, which ensures the frequency spectrum(50 Hz~4 kHz) the hydrophone interested in free from the interference of the encapsulation resonance, broadening the working frequency band. The sensitivity of the optimal encapsulation has been improved to (-170±2) dB,almost the same with the bare chip,and the maximum diameter of the hydrophone has been reduced from 36 mm to 28 mm,miniaturizing the hydrophone further.

著录项

  • 来源
    《传感技术学报》 |2014年第1期|21-25|共5页
  • 作者单位

    中北大学仪器科学与动态测试教育部重点实验室;

    太原030051;

    中北大学电子测试技术重点实验室;

    太原030051;

    中北大学仪器科学与动态测试教育部重点实验室;

    太原030051;

    中北大学电子测试技术重点实验室;

    太原030051;

    中北大学仪器科学与动态测试教育部重点实验室;

    太原030051;

    中北大学电子测试技术重点实验室;

    太原030051;

    中北大学仪器科学与动态测试教育部重点实验室;

    太原030051;

    中北大学电子测试技术重点实验室;

    太原030051;

  • 原文格式 PDF
  • 正文语种 chi
  • 中图分类 TP565.1;
  • 关键词

    MEMS仿生水听器; 丁腈橡胶帽封装; 频率; 灵敏度; 小型化;

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号