首页> 中文期刊>色谱 >色谱/原子吸收联用系统中卧管式微火焰原子化离子化同步检测器的研究与应用

色谱/原子吸收联用系统中卧管式微火焰原子化离子化同步检测器的研究与应用

     

摘要

介绍了一种新型的卧管式微火焰原子化离子化同步检测器,对其结构、工作原理及性能进行了研究。将其应用到色谱/原子吸收联用系统中,实现了有机金属化合物以及与其共存的有机化合物的同步检测。有机金属化合物(二乙基汞)的原子吸收信号检出限为2.5×10-11g/s;有机化合物(苯)的离子化信号检出限为1.0×10-11g/s。%Gas chromatography/atomic absorption spectroscopy(GC/AAS) is agood me thod for the species analysis of organometallic compounds. But the traditi o nal atomizers are not very suitable for this technology and all of them response only to one kind of signal - the conc e ntration of the metallic atoms of the ground state. They can not give any info r mation about the organic group of organometallic compounds and organic compound s which coexist with the former. For GC/AAS we want to design and manufacture a n ew kind of detector which is much more sensitive and has a much smaller dead vol ume and will sensitively and synchronousl y response to the atomization signal of organometallic compound and ionization s ignal of organic compound. The authors have noticed that the atomization of o r ganometallic compound and ionization of organic compound have been existing in t he same hydrogen flame. The question is how to gain and exchange and output the two signals which are completely different in characters. For this purpose we de signed and manufactured a new type of horizontal pipe mini-flame atomization an d ionization synchronous detector. The key part is a T type glass tube (80 mm× 13 mm×10 mm i.d.) w hich covers horizontally on the jet of the mini-flame atomizer and a long p i pe stainless steel collector (70 mm×9.5 mm o.d.×9 mm i.d.) is tightly ins erted in the tube. The light beam of the hollow cathode lamp passes through the hydroge n flame along the axial center of the glass tube and the ground state metallic at o ms in the flame diffuses to both ends of the tube along the axial center of the g lass tube too. This process enriches the depth of the light absorption and then increases the sensitivity of atomization. At the same time the long pipe collec t or can enrich the collection efficiency of the ionization and increases the sens itivity and widens the linear range. So the detector can synchronously and sens itively detect the organometallic and organic compounds. The detection li mit for atomization of the organometallic compound(diethylmercury) is 2.5×10-11g.s-1 and for ionization of the organic compound (benzene) is 1.0×10-11g.s-1. The linear range is 7.0×102 for atomization of diethylmercury (r=0.9 98 9) and 2 .5×105 for ionization of benzene (r=0.999 2). The selectivity of the detector t o the organic solvent under the optimum operating condition of atomization i s 104-107. The relative standard deviation (RSD,n=11) of the peak area in the optimum operating conditions of atomization for the organometallic compound (die thylmercury) and of ionization for the organic compound (benzene) is 1.8% and 1 .5% respectively. Under the same operating condition, the atomization and the i onization can not reach the optimum performance at the same time. If the atomiz a tion is in the optimum performance state, the performance for ionization is like a chromatographic thermal conductivity detector(TCD). The opti m um performance of the atomization and ionization can be quickly adjusted by chan ging the flow rates of the corresponding gases such as H2,N2 and air.

著录项

相似文献

  • 中文文献
  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号