首页> 外文学位 >Pulsed electric field processing of functional foods.
【24h】

Pulsed electric field processing of functional foods.

机译:功能食品的脉冲电场处理。

获取原文
获取原文并翻译 | 示例

摘要

Pulsed electric field (PEF) is a nonthermal alternative to traditional food processing. PEF is effective in microbial inactivation without significant impair on food quality, including flavor, nutrition, and physical properties such as color, viscosity and electric conductivity. Dielectric breakdown of cellular membrane in microorganisms has been widely accepted as the mechanism corresponding to microbial inactivation by PEF. To execute its microbial inactivation effect, PEF needs to acquire electric field strength higher than the critical value that can induce higher than 1 volt of transmembrane potential to most of the vegetative cells. Inactivation of food enzymes has been extensively studied since 1960s. Inactivation effect of PEF depends on both the dosage and the structures of the target enzymes.;PEF is effective in inactivating natural flora and can significantly extend microbial stability of the bovine milk concentrate enriched soymilk. PEF treatment at higher electric field strength shows higher natural flora inactivation and results in higher microbial stability during a 30-day storage test at 4°C. PEF treatment at 41.1kV/cm for 54mus inactivates 5.3 logs of natural flora population (p 0.01). With continuous thermal processing, 78°C for 120s is needed to achieve same microbial inactivation. Temperature increase per pair of PEF treatment chambers (dT), with inlet temperature (T 1) ranging from 13°C to 27°C and electric field strength ranging from 0 to 38kV/cm, is primarily a function of electric field strength and energy input. Sample inlet temperature does not show significant influences on dT. However, T1 determines the maximum temperature induced in PEF treatment chambers. PEF significantly inactivates E. coli 8739 cells (p 0.05). The inactivation effect increases with the increase of electric field strength and the number of pulses delivered to samples. When electric field strength is higher than 30kV/cm, increase in treatment time and sample inlet temperature cause an increase in PEF inactivation of E. coli 8739. Nevertheless, when electric field strength is lower than 25kV/cm, the microbial inactivation effect of treatment time and T 1 is negligible. Experimental data illustrate that the microbial inactivation effect of PEF is due to the high intensity of electric field strength. Thermal effect contributes minimal to the total inactivation of natural flora and E. coli 8739. (Abstract shortened by UMI.)
机译:脉冲电场(PEF)是传统食品加工的一种非热替代方法。 PEF可有效灭活微生物,而不会显着损害食品的质量,包括风味,营养以及诸如颜色,粘度和电导率的物理特性。微生物中细胞膜的介电击穿已被广泛接受为与PEF使微生物失活相对应的机制。为了执行其微生物灭活作用,PEF需要获得高于临界值的电场强度,该电场强度可以使大多数营养细胞产生高于1伏的跨膜电位。自1960年代以来,对食物酶的灭活进行了广泛的研究。 PEF的灭活效果取决于目标酶的剂量和结构。PEF可有效灭活天然菌群,并可显着延长富含牛乳的豆浆的微生物稳定性。在较高的电场强度下进行PEF处理显示出较高的天然菌群失活率,并在4°C下进行30天的储存测试期间,具有较高的微生物稳定性。 PEF以41.1kV / cm处理54mus灭活了5.3 log的自然菌群(p <0.01)。通过连续热处理,需要78°C持续120s才能实现相同的微生物灭活。每对PEF处理室的温度升高(dT),入口温度(T 1)为13°C至27°C,电场强度为0至38kV / cm,主要是电场强度和能量的函数输入。样品入口温度对dT没有显着影响。但是,T1确定了PEF处理室中引起的最高温度。 PEF显着灭活大肠杆菌8739细胞(p <0.05)。灭活效果随电场强度的增加和传递给样品的脉冲数的增加而增加。当电场强度高于30kV / cm时,处理时间的增加和样品入口温度的增加会导致E. coli 8739的PEF失活增加。但是,当电场强度低于25kV / cm时,处理的微生物失活效果时间和T 1可以忽略不计。实验数据表明,PEF的微生物灭活作用是由于高电场强度引起的。热效应对自然菌群和大肠杆菌8739的总灭活的贡献很小。(摘要由UMI缩短。)

著录项

  • 作者

    Li, Siquan.;

  • 作者单位

    The Ohio State University.;

  • 授予单位 The Ohio State University.;
  • 学科 Agriculture Food Science and Technology.;Health Sciences Nutrition.
  • 学位 Ph.D.
  • 年度 2003
  • 页码 226 p.
  • 总页数 226
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号