首页> 外文会议>World conference on earthquake engineering;WCEE >AN ANALYSIS OF FIRE SPRINKLER SYSTEM FAILURES DURING THENORTHRIDGE EARTHQUAKE AND COMPARISON WITH THE SEISMIC DESIGNSTANDARD FOR THESE SYSTEMS
【24h】

AN ANALYSIS OF FIRE SPRINKLER SYSTEM FAILURES DURING THENORTHRIDGE EARTHQUAKE AND COMPARISON WITH THE SEISMIC DESIGNSTANDARD FOR THESE SYSTEMS

机译:北R地震期间消防喷淋器系统故障的分析及其与系统抗震设计标准的比较

获取原文

摘要

This study analyzes fire sprinkler system failure data from the Northridge Earthquake and compares thefindings with the primary seismic design standard applied to sprinkler systems, National Fire ProtectionAssociation (NFPA) 13, Installation of Sprinkler Systems. The intent of this paper is not to perform arigorous examination of the data as compared to NFPA 13 requirements, but to instead present theapplicability of this type of loss data when quantifying the seismic design requirements applicable to firesprinkler systems.
机译:这项研究分析了北岭地震的消防喷水灭火系统故障数据,并将发现的结果与应用于喷水灭火系统的主要抗震设计标准(美国国家消防协会(NFPA)13,喷水灭火系统的安装)进行了比较。与NFPA 13要求相比,本文的目的不是对数据进行严格检查,而是在量化适用于喷水灭火系统的抗震设计要求时,提出此类损失数据的适用性。