首页> 外文会议>World conference on earthquake engineering;WCEE >FRICTION DAMPERS FOR SEISMIC UPGRADE OFST. VINCENT HOSPITAL, OTTAWA
【24h】

FRICTION DAMPERS FOR SEISMIC UPGRADE OFST. VINCENT HOSPITAL, OTTAWA

机译:ST地震升级的摩擦阻尼器。渥太华文森特医院

获取原文

摘要

St. Vincent Hospital comprises of five blocks of 5-storey concrete frame construction. One of the blocksis new construction and the other four blocks were built between 1890 and the early 1950's. Theearthquake resistance of the existing structures was significantly less than that required by the currentbuilding codes. Since hospitals are of post disaster importance, the engineers recommended that theexisting structures be upgraded along with the new expansion.Conventional methods of seismic rehabilitation with concrete shearwalls or rigid steel bracing were notconsidered suitable for this hospital as upgrades with these methods would have required expensive andtime consuming foundation work. Supplemental damping in conjunction with appropriate stiffness offeredan innovative and attractive solution for the seismic rehabilitation of this hospital. This was achieved byintroducing Pall Friction Dampers in steel bracing.
机译:圣文森特医院由五层5层高的混凝土框架结构组成。其中一个街区是新建筑,其他四个街区则建于1890年至1950年代初期。现有结构的抗震能力明显低于现行建筑规范的要求。由于医院在灾难后很重要,因此工程师建议对现有结构进行升级,同时进行新的扩建。不考虑采用混凝土剪力墙或刚性钢支撑进行地震恢复的常规方法,因为这种方法的升级需要昂贵且耗时的方法。消耗基础工作。补充阻尼和适当的刚度为该医院的地震修复提供了一种新颖而有吸引力的解决方案。这是通过在钢制支撑中引入颇尔摩擦阻尼器来实现的。