首页> 外文会议>Wearable sensors and robots >One-Handed Wearable sEMG Sensor for Myoelectric Control of Prosthetic Hands
【24h】

One-Handed Wearable sEMG Sensor for Myoelectric Control of Prosthetic Hands

机译:单手可穿戴式sEMG传感器,用于假肢手的肌电控制

获取原文
获取原文并翻译 | 示例

摘要

A novel sEMG (surface electromyography) sensor using polypyrrole-coated nonwoven fabric sheet as electrodes (PPy-electrode) is proposed for the disabled to control prosthetic limbs in daily life. The PPy-electrodes are sewed on an elastic band to guarantee closely contact to the skin thus to enable stable sEMG measurement with high signal-to-noise ratio. Furthermore, the sensor is highly customizable to fit for the size and the shape of the stump so that the disabled can wear the sensor by themselves. The performance of the proposed sensor is investigated by comparing with Ag/AgCl electrodes with electrolytic gel in an experiment to measure the sEMG from the same muscle fibers. The high correlation coefficient (0.87) between the sEMG measured by the two types of sensors suggests the effectiveness of the proposed sensor. The experiment to control myoelectric prosthetic hands showed that the disabled can use it with one hand to obtain sEMG signals for myoelectric control.
机译:提出了一种新型的sEMG(表面肌电图)传感器,该传感器使用聚吡咯涂层无纺布片作为电极(PPy电极),用于残疾人在日常生活中控制假肢。将PPy电极缝在松紧带上,以确保与皮肤紧密接触,从而能够以高信噪比进行稳定的sEMG测量。此外,该传感器高度可定制,以适合树桩的大小和形状,因此残疾人可以自己佩戴传感器。通过与带有电解凝胶的Ag / AgCl电极进行比较,在同一实验中测量该传感器的性能,以测量同一肌肉纤维的sEMG。两种传感器测得的sEMG之间的高相关系数(0.87)表明了所提出传感器的有效性。控制肌电假肢手的实验表明,残疾人可以用一只手来获取用于肌电控制的sEMG信号。

著录项

  • 来源
    《Wearable sensors and robots》|2015年|105-109|共5页
  • 会议地点 Hangzhou(CN)
  • 作者单位

    Brain Science Inspired Life Support Research Center, The University of Electro-Communications, Tokyo 1828585, Japan;

    Department of Mechanical Engineering and Intelligent Systems, The University of Electro-Communications, Tokyo 1828585, Japan;

    Department of Mechanical Engineering and Intelligent Systems, The University of Electro-Communications, Tokyo 1828585, Japan;

    Brain Science Inspired Life Support Research Center, The University of Electro-Communications, Tokyo 1828585, Japan;

    Brain Science Inspired Life Support Research Center, The University of Electro-Communications, Tokyo 1828585, Japan,Department of Mechanical Engineering and Intelligent Systems, The University of Electro-Communications, Tokyo 1828585, Japan;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Surface electromyography; EMG electrodes; Polypyrrole-coated nonwoven fabric sheet; Prosthetic hand;

    机译:表面肌电图;肌电电极聚吡咯涂层无纺布片;假手;
  • 入库时间 2022-08-26 14:03:34

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号