The diagnostic upper port plug in ITER is a long metal box cantilevered to the vacuum vessel port with 42 × M52 studs and nuts. The plug structure has a heavy payload at the front such as the Diagnostic First Wall (DFW) and the Diagnostic Shield Module (DSM) to protect the diagnostic components from plasma and neutron fluxes. This kind of structural configuration is susceptible to a resonance with the transient external load. For the upper port plug, the design-driving load is electromagnetic (EM) forces due to plasma disruptions. In this study the dynamic amplification factor (DAF) of the structure is calculated for such EM loads. The bolted joint at the back flange of the plug structure is also taken into account together with the port extension of the vacuum vessel and its influence on the dynamic behavior is investigated. The analysis results show that the bolted joint reduces the DAF as well as the natural frequency of the structure.
机译:诊断性ITER的上部端口插头是一个长金属盒,带有42×M52螺柱和螺母,悬于真空容器端口。插头结构的前端有大量有效负载,例如诊断第一壁(DFW)和诊断屏蔽模块(DSM),以保护诊断组件免受等离子体和中子通量的侵害。这种结构配置容易受到瞬态外部负载的共振。对于上端口插头,设计驱动负载是由于等离子体破坏而产生的电磁(EM)力。在这项研究中,针对此类EM载荷计算了结构的动态放大系数(DAF)。还考虑了插头结构后法兰上的螺栓连接以及真空容器的端口延伸,并研究了其对动态行为的影响。分析结果表明,螺栓连接降低了DAF以及结构的固有频率。