【24h】

Fluorescent Intensity of Dye Solutions under Different pH Conditions

机译:不同pH条件下染料溶液的荧光强度

获取原文
获取原文并翻译 | 示例

摘要

Fluorescent tracers are widely used for assessment of spray quantity in the field due to their relatively high sensitivity, low cost and user safety. However, many concerns have been raised over their measurement accuracy due to questions of stability of fluorescence during tests. Stable analysis of fluorescence is essential to ensure accurate evaluation of pesticide spray application efficiency. The objective of this research was to determine the stability of fluorescent intensity of five tracers dissolved in solutions with various pH conditions in an effort to minimize analytical errors in the measurement of spray deposition and drift. The fluorescent intensity of five fluorescent tracers commonly used for the quantitative assessment of spray deposition and off-target loss was investigated with wash solutions over pH conditions from 6.9-10.4. The tracers selected in the tests were Brilliant Sulfaflavine (BSF), Fluorescein, Pyranine, Tinopal, and Eosin. The fluorescence of Pyranine was the most sensitive to the solution pH conditions, followed by Fluorescein and Tinopal, while BSF and Eosin had a nearly constant fluorescent intensity over the pH range from 6.9-10.4. The fluorescence of Fluorescein increased 1.3 times, Tinopal 1.25 times, and Pyranine 3.0 times as the pH value increased from 6.9-8.4, but it became nearly constant when pH value was greater than 8.4. However, Pyranine, Fluorescein, and Tinopal showed much stronger fluorescence than BSF and Eosin. A solution containing Fluorescein at pH 8.4 and higher demonstrated 83 times greater fluorescent intensity than the solution containing the same amount of BSF. In conclusion, the fluorescence of tracers should be examined under various pH conditions during the selection of tracers for pesticide spray deposition and drift trials.
机译:荧光示踪剂由于其相对较高的灵敏度,低成本和用户安全性而被广泛用于现场喷雾量的评估。然而,由于测试过程中荧光的稳定性问题,人们对其测量精度提出了许多关注。稳定的荧光分析对于确保准确评估农药喷雾施用效率至关重要。这项研究的目的是确定在不同pH条件下溶解于溶液中的五种示踪剂的荧光强度的稳定性,以最大程度地减少喷雾沉积和漂移测量中的分析误差。在pH值为6.9-10.4的条件下,使用洗涤液对五种荧光示踪剂的荧光强度进行了荧光定量,这些荧光示踪剂通常用于定量评估喷雾沉积和脱靶损失。在测试中选择的示踪剂是辉煌的磺胺黄素(BSF),荧光素,吡喃,蒂诺帕和曙红。吡喃氨酸的荧光对溶液的pH条件最敏感,其次是荧光素和Tinopal,而BSF和曙红在6.9-10.4的pH范围内具有几乎恒定的荧光强度。当pH值从6.9-8.4增加时,荧光素的荧光增加1.3倍,蒂诺泊(Tinopal)1.25倍,吡喃(Pyranine)3.0倍,但是当pH值大于8.4时,荧光几乎恒定。但是,吡喃宁,荧光素和蒂诺泊尔的荧光要比BSF和曙红强得多。含有荧光素的pH值为8.4或更高的溶液,其荧光强度是含有相同量的BSF的溶液的83倍。总之,在选择用于农药喷雾沉积和漂移试验的示踪剂时,应在各种pH条件下检查示踪剂的荧光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号