首页> 外文会议>Symposium on Pesticide Formulation and Delivery Systems >Fluorescent Intensity of Dye Solutions under Different pH Conditions
【24h】

Fluorescent Intensity of Dye Solutions under Different pH Conditions

机译:不同pH条件下染料溶液的荧光强度

获取原文

摘要

Fluorescent tracers are widely used for assessment of spray quantity in the field due to their relatively high sensitivity, low cost and user safety. However, many concerns have been raised over their measurement accuracy due to questions of stability of fluorescence during tests. Stable analysis of fluorescence is essential to ensure accurate evaluation of pesticide spray application efficiency. The objective of this research was to determine the stability of fluorescent intensity of five tracers dissolved in solutions with various pH conditions in an effort to minimize analytical errors in the measurement of spray deposition and drift. The fluorescent intensity of five fluorescent tracers commonly used for the quantitative assessment of spray deposition and off-target loss was investigated with wash solutions over pH conditions from 6.9-10.4. The tracers selected in the tests were Brilliant Sulfaflavine (BSF), Fluorescein, Pyranine, Tinopal, and Eosin. The fluorescence of Pyranine was the most sensitive to the solution pH conditions, followed by Fluorescein and Tinopal, while BSF and Eosin had a nearly constant fluorescent intensity over the pH range from 6.9-10.4. The fluorescence of Fluorescein increased 1.3 times, Tinopal 1.25 times, and Pyranine 3.0 times as the pH value increased from 6.9-8.4, but it became nearly constant when pH value was greater than 8.4. However, Pyranine, Fluorescein, and Tinopal showed much stronger fluorescence than BSF and Eosin. A solution containing Fluorescein at pH 8.4 and higher demonstrated 83 times greater fluorescent intensity than the solution containing the same amount of BSF. In conclusion, the fluorescence of tracers should be examined under various pH conditions during the selection of tracers for pesticide spray deposition and drift trials.
机译:由于其相对高的灵敏度,低成本和用户安全性,荧光示踪剂广泛用于评估现场的喷雾量。然而,由于荧光期间的荧光稳定性问题,许多担忧已经过度提出了它们的测量准确性。荧光稳定分析对于确保对农药喷涂效率准确评估至关重要。该研究的目的是确定溶解在溶液中的五种示踪剂的荧光强度的稳定性,各种pH条件是为了最小化喷射沉积和漂移测量中的分析误差。在6.9-10.4的pH条件下,研究了通常用于定量评估喷雾沉积和脱靶损失的定量评估的五种荧光示踪剂的荧光强度。在测试中选择的示踪剂是辉煌的Sulfaflavine(BSF),荧光素,吡喃啶,Tinopal和eosin。吡喃啶的荧光是溶液pH条件最敏感的,其次是荧光素和锡峰,而BSF和eosin在pH范围内具有几乎恒定的荧光强度从6.9-10.4。荧光素的荧光增加1.3倍,锡垂达1.25倍,吡喃啶从6.9-8.4增加时增加3.0倍,但当pH值大于8.4时,它变得几乎恒定。然而,吡喃啶,荧光素和Tinopal呈比BSF和曙红显示得多。含有pH8.4的荧光素的溶液和更高的荧光强度均比含有相同量的BSF的溶液更高的83倍。总之,在选择种类的农药喷雾沉积和漂移试验期间,应在各种pH条件下检查示踪剂的荧光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号