Glass fiber reinforced polymer (GFRP) bars were placed under load in concrete beams for periods of time as long as three years in natural and harsh environments. Following flexural loading, the bars were carefully extracted from the beams and tested in order to evaluate residual tensile properties. It was found that the tensile strength decreased in the highly aggressive conditions but not in the natural conditions. The modulus of elasticity and ultimate strain did not change appreciably in any of the four conditions. Analysis of selected bars using thermo-mechanical analysis indicated only slight effects of conditioning on glass transition temperature and transverse coefficient of thermal expansion. Energy dispersive x-ray spectroscopy indicated no signs of damage, loss of cross section, orchange in material composition of the bars.
机译:在自然和恶劣的环境中,玻璃纤维增​​强的聚合物(GFRP)钢筋在混凝土梁的荷载下放置了长达三年的时间。弯曲载荷后,将钢筋从梁中小心取出并进行测试,以评估残余拉伸性能。发现在高侵蚀性条件下拉伸强度降低,但在自然条件下未降低。在这四个条件下,弹性模量和极限应变均没有明显变化。使用热机械分析法分析选定的钢筋,表明调理对玻璃化转变温度和横向热膨胀系数的影响很小。能量色散X射线光谱表明没有损坏的迹象,横截面的损失或棒的材料组成的变化。