首页> 外文会议>Scantek, Inc.;National conference on noise control engineering;Institute of Noise Control Engineering of the USA >Measuring High Frequency Valve Noise to Evaluate Interference with Ultrasonic Flow Meters
【24h】

Measuring High Frequency Valve Noise to Evaluate Interference with Ultrasonic Flow Meters

机译:测量高频阀噪声以评估超声波流量计的干扰

获取原文

摘要

Ultrasonic flow meters are installed in lines with particular concern on the location of flow noisesources, such as valves and other geometry changes and restrictions in a piping system. Theultrasonic flow meter operates with a tone burst, typically in the range of 100 to 300 kHz. While,this frequency range is far above the typical range for noise control in piping systems, there isgood evidence that the flow noise sources generate sound in the operating frequency range of theultrasonic flow meter. The goal of the work was to establish a procedure to measure the noisegenerated by piping elements in the frequency range of the ultrasonic flow meter operation. Theflow disturbance is placed upstream of the ultrasonic flow meter. The internal noise spectrumare measured at three locations, one upstream of the flow disturbance, one between the flowdisturbance and the flow meter and one down stream of the flow meter. Some available resultsin the literature will be reviewed along with presenting the experimental setup and preliminaryresults. The results will show the capabilities of the measurements in this frequency range.
机译:超声波流量计的安装要特别注意流动噪声源的位置,例如阀门和其他几何形状的变化以及管道系统中的限制。超音波流量计通常在100到300 kHz的范围内以音调突发工作。尽管此频率范围远高于管道系统中噪声控制的典型范围,但有充分的证据表明,流动噪声源会在超声波流量计的工作频率范围内产生声音。该工作的目标是建立一个程序,以测量在超声流量计运行的频率范围内管道元件产生的噪声。流量干扰放置在超声波流量计的上游。内部噪声频谱在三个位置进行测量,一个位于流扰动的上游,一个位于流扰与流量计之间,一个位于下游。文献中的一些可用结果将与实验设置和初步结果一起进行回顾。结果将显示在该频率范围内的测量能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号