【24h】

User Acceptance and Psychological Reactions to Respiratory and Body Protective Devices for a Cold Environment

机译:寒冷环境中呼吸和身体防护设备的用户接受度和心理反应

获取原文
获取原文并翻译 | 示例

摘要

The aim of the present study was to evaluate two different respiratory protective devices (RPD) and two body protective devices (BPD) in respect of acceptance and psychological reactions. The protective devices were designed to be used by rescue personnel in NBC-contaminated environments. The evaluation was carried out under three environmental conditions; from room temperature to -20℃, 30 minutes in -20℃ and from -20℃ to room temperature. During the 30 minutes in -20℃ the participants were to the following four activities; no activity (7 minutes), carry sandbags (7 minutes), walk in stairs (7 minutes), and read text (9 minutes). 10 persons between 32 and 54 years of age participated in this study. There were 3 men and 7 women and none of them had any prior experience of wearing RPD or BPD. All participants tested the two RPDs (Full face mask 90 and TST) as well as the two BPDs (SRV and TST). The following main results were found; The use of RPD and BPD in general always creates discomfort and disturbance for the users but not severe enough to prevent using the protective devices for as long as it is considered necessary. Though there are some significant differences between the two RPDs. The sound level was judged higher for TST than for Full face mask 90 (p< .07). TST was experienced more open and with more space compared to Full face mask 90 (p< .01). In the cold environment TST was colder then Full face mask 90 (p< .04) and when changing from the cold environment to room temperature the visibility in TST was significantly worse than in Full face mask 90 (p< .10). The BPDs were judged as equal in discomfort and constraint except for the cold environment condition where TST was experienced as colder than SRV (p< .08) and when changing from the cold environment to room temperature where SRV was experienced as warmer than TST (p< .06)
机译:本研究的目的是评估两种不同的呼吸防护装置(RPD)和两种身体防护装置(BPD)的接受度和心理反应。这些防护设备旨在供NBC污染环境中的救援人员使用。评估是在三种环境条件下进行的;从室温到-20℃,在-20℃30分钟,从-20℃到室温。在-20℃下的30分钟内,参与者参加了以下四项活动:不活动(7分钟),背着沙袋(7分钟),走楼梯(7分钟),阅读文字(9分钟)。 32至54岁之间的10人参加了这项研究。男3例,女7例,没有一个人曾经戴过RPD或BPD。所有参与者都测试了两个RPD(全面罩90和TST)以及两个BPD(SRV和TST)。发现以下主要结果;通常,RPD和BPD的使用通常会给用户带来不适和干扰,但严重程度不足以防止在必要时使用保护装置。尽管两个RPD之间存在一些显着差异。 TST的声音等级被判定为比全脸罩90的更高(p <.07)。与全脸面罩90(p <.01)相比,TST的体验更加开放,空间更大。在寒冷的环境中,TST比全面罩90更冷(p <.04),并且当从寒冷的环境变为室温时,TST中的可见度明显比全面罩90(p <.10)差。 BPD在不适感和约束力方面均被认为是相等的,除了寒冷的环境条件(其中TST的温度低于SRV(p <.08))以及从寒冷的环境变为室温(SRV的温度高于TST(p <0.08)) <.06)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号