首页> 外文会议>Photonics, devices, and systems VI >Experimental and theoretical study of deformable mirror actuator arrays
【24h】

Experimental and theoretical study of deformable mirror actuator arrays

机译:变形镜致动器阵列的实验和理论研究

获取原文
获取原文并翻译 | 示例

摘要

Deformable mirrors have gained increasing interest in many different fields of application including laser physics, and they are becoming a universal tool for correcting optical aberrations of laser beams especially in large scale laser systems. One of the most common types of deformable mirror is a bimorph design which uses two plates of piezo-material to which single electrodes are connected. These electrodes form the actuator array and their layout defines the resulting performance of the mirror to some extent. In the end all types of deformable mirrors currently used use an actuator array of some sort. To estimate the significance and effect of different actuator layout and shapes of actuators, an experimental study was performed. Four different commonly used actuator arrays were compared using photo-controlled deformable mirror. Using such device allows to study the effect of actuator layout separately from all other effects, since the device remains the same including all its imperfections. The experimental results are compared with numerical simulations and discussion is presented.
机译:可变形反射镜在包括激光物理学在内的许多不同应用领域中越来越引起人们的兴趣,并且它们正成为校正激光束光学像差的通用工具,尤其是在大型激光系统中。最常见的可变形反射镜类型之一是双压电晶片设计,该设计使用两块压电材料板,单电极连接到该两块压电材料板上。这些电极形成致动器阵列,它们的布局在一定程度上定义了反射镜的最终性能。最后,当前使用的所有类型的可变形镜都使用某种类型的致动器阵列。为了评估不同执行器布局和执行器形状的重要性和影响,进行了一项实验研究。使用光控可变形反射镜比较了四个不同的常用执行器阵列。使用这种设备可以将致动器布局的影响与所有其他影响分开研究,因为该设备(包括其所有缺陷)保持不变。将实验结果与数值模拟进行比较并进行讨论。

著录项

  • 来源
    《Photonics, devices, and systems VI》|2014年|945010.1-945010.6|共6页
  • 会议地点 Prague(CZ)
  • 作者单位

    Hilase Centre, Institute of Physics AS CR v.v.i., Za Radnici 828, 52541, Dolni Brezany, Czech Republic,Department of Physical Electronics, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Brehova 7, 11519, Prague, Czech Republic;

    Hilase Centre, Institute of Physics AS CR v.v.i., Za Radnici 828, 52541, Dolni Brezany, Czech Republic,LUXOR laboratory, CNR IFN, Via Trasea 7, 35131, Padova, Italy;

    Hilase Centre, Institute of Physics AS CR v.v.i., Za Radnici 828, 52541, Dolni Brezany, Czech Republic;

    Department of Physical Electronics, Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague, Brehova 7, 11519, Prague, Czech Republic;

    Hilase Centre, Institute of Physics AS CR v.v.i., Za Radnici 828, 52541, Dolni Brezany, Czech Republic;

  • 会议组织
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    adaptive optics; deformable mirror; actuator array;

    机译:自适应光学变形镜执行器阵列;
  • 入库时间 2022-08-26 13:45:07

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号